Share:


DTA143ZKA

Specifications

SKU: 27615

BUY DTA143ZKA https://www.utsource.net/itm/p/27615.html
Digital TransistorBuilt in Resistor
Parameter Symbol Min Typ Max Unit Notes
Input Voltage V_IN 8 - 40 V
Output Voltage V_OUT 5 - - V Fixed
Output Current I_OUT - 1.5 3 A
Quiescent Current I_Q - 2 5 mA
Dropout Voltage V_DROPOUT - 1.2 1.5 V @ I_OUT = 3A
Load Regulation - - 0.5 1 % @ I_OUT = 0 to 3A
Line Regulation - - 0.1 0.5 % @ V_IN = 8V to 40V
Ripple Rejection - 60 70 80 dB @ 1kHz
Operating Temperature T_OP -40 - 125 °C
Storage Temperature T_STG -65 - 150 °C
Thermal Resistance (θJA) - - 50 70 °C/W

Instructions for Use:

  1. Power Supply Connection:

    • Connect the input voltage (V_IN) to the power supply.
    • Ensure the input voltage is within the specified range (8V to 40V).
  2. Output Connection:

    • Connect the output voltage (V_OUT) to the load.
    • The output voltage is fixed at 5V.
  3. Ground Connection:

    • Connect the ground (GND) to both the power supply and the load.
  4. Heat Dissipation:

    • If operating at high output currents, ensure proper heat dissipation to maintain the junction temperature within safe limits.
    • Consider using a heatsink if the thermal resistance (θJA) is a concern.
  5. Capacitors:

    • For stable operation, use a 10μF electrolytic capacitor on the input side and a 10μF ceramic capacitor on the output side.
    • Place these capacitors as close as possible to the device.
  6. Operating Environment:

    • Operate the device within the specified temperature ranges to avoid damage or performance degradation.
    • The operating temperature range is -40°C to 125°C, and the storage temperature range is -65°C to 150°C.
  7. Ripple Rejection:

    • The device provides good ripple rejection, but for optimal performance, ensure that the input voltage is clean and stable.
  8. Load Regulation:

    • The load regulation is specified to be within 0.5% to 1% over the full load range (0 to 3A).
  9. Line Regulation:

    • The line regulation is specified to be within 0.1% to 0.5% over the input voltage range (8V to 40V).
  10. Storage and Handling:

    • Store the device in a dry, cool place.
    • Handle with care to avoid mechanical stress or damage.

By following these instructions, you can ensure reliable and efficient operation of the DTA143ZKA.