Specifications
SKU: 226897
DIODE SCHOTTKY SINGLE 50V 333mW 0.41V-vf 15mA-IFM 1mA-IF 0.2uA-IR SOD-123 3K/REEL
Parameter | Symbol | Min | Typ | Max | Unit | Notes |
---|---|---|---|---|---|---|
Supply Voltage | VCC | 4.5 | - | 18 | V | - |
Quiescent Current | IQ | - | 2 | 3 | mA | - |
Input Voltage Range | VIN | 0 | - | VCC-1.5 | V | - |
Output Voltage Range | VOUT | 0.01 | - | VCC-0.01 | V | - |
RMS Input Voltage Range | VRMS | 0 | - | 10 | V | - |
Output Accuracy | - | - | ±0.1 | ±1.0 | % | - |
Linearity Error | - | - | ±0.01 | ±0.1 | % | - |
Temperature Range | TA | -40 | - | 85 | °C | - |
Operating Frequency Range | fIN | 0 | - | 20 | kHz | - |
Instructions for Using AD636JD
Power Supply:
- Connect the positive supply voltage (VCC) to pin 8 and ground (GND) to pin 4.
- Ensure the supply voltage is within the range of 4.5V to 18V.
Input Signal:
- Connect the input signal to pins 5 (non-inverting input) and 6 (inverting input).
- The input voltage should be within the range of 0V to VCC - 1.5V.
- For AC signals, ensure the RMS voltage does not exceed 10V.
Output Signal:
- The output signal is available at pin 7.
- The output voltage range is from 0.01V to VCC - 0.01V.
- The output is a DC voltage proportional to the RMS value of the input signal.
Biasing and Decoupling:
- Place a 0.1μF capacitor between VCC and GND close to the device to filter out noise.
- If the input signal is AC-coupled, use appropriate biasing techniques to ensure the input remains within the valid range.
Temperature Considerations:
- The device operates over a temperature range of -40°C to 85°C.
- Ensure the operating environment is within this range to maintain accuracy and reliability.
Frequency Response:
- The device is designed to handle input frequencies up to 20kHz.
- For higher frequencies, consider the effects on accuracy and linearity.
Accuracy and Linearity:
- The output accuracy is typically ±0.1% and can vary up to ±1.0%.
- Linearity error is typically ±0.01% and can vary up to ±0.1%.
Handling and Storage:
- Handle the device with care to avoid static damage.
- Store in a dry, cool place away from direct sunlight and extreme temperatures.
By following these guidelines, you can ensure optimal performance and reliability of the AD636JD.