Specifications
SKU: 331585
16-BIT MONOLITHIC TRACKING RESOLVER (LVDT)-TO-DIGITAL CONVERTERS
Parameter | Value | Unit |
---|---|---|
Input Voltage Range | 4.5 to 55 | V |
Output Voltage | 0.8 to 5.5 | V |
Output Current | Up to 2 | A |
Efficiency | Up to 97% | % |
Switching Frequency | 300 to 2000 | kHz |
Operating Temperature | -40 to +125 | °C |
Storage Temperature | -65 to +150 | °C |
Protection Features | Overcurrent, Overvoltage, Thermal Shutdown | - |
Package Type | QFN-20 | - |
Size | 5 x 5 x 1.2 | mm |
Instructions for Use:
Power Supply Connection:
- Connect the input voltage (VIN) to the power supply within the specified range (4.5V to 55V).
- Ensure the input voltage is stable and within the operating range to avoid damage to the device.
Output Configuration:
- Set the output voltage (VOUT) using the external feedback resistor network.
- Refer to the datasheet for specific resistor values to achieve the desired output voltage.
Thermal Management:
- Ensure adequate heat dissipation by mounting the device on a heatsink or PCB with good thermal conductivity.
- Monitor the operating temperature to prevent overheating.
Protection Circuits:
- The device includes overcurrent, overvoltage, and thermal shutdown protection. These features will automatically engage if the device detects abnormal conditions.
- In the event of a protection circuit activation, investigate the cause and correct it before reapplying power.
Layout Considerations:
- Place the input and output capacitors as close as possible to the device to minimize parasitic inductance.
- Use wide traces for high-current paths to reduce resistance and improve efficiency.
Testing and Validation:
- Before deploying the device in a final application, perform thorough testing under all expected operating conditions.
- Validate the performance and reliability of the power supply design to ensure it meets the system requirements.
Storage and Handling:
- Store the device in a dry, cool environment to prevent moisture damage.
- Handle the device with care to avoid static discharge and physical damage.
Inquiry - RDC19200-302