Specifications
SKU: 382935
N CHANNEL MOS TYPE CHOPPER GEGULATORS DC-DC CONVERTER, AND MOTOR DRIVE APPLICATIONS
Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
---|---|---|---|---|---|---|
Drain-Source Voltage | V(DS) | - | 500 | - | V | - |
Gate-Source Voltage | V(GS) | -20 | - | 20 | V | - |
Drain Current | I(D) | - | 10 | - | A | V(DS) = 500V, Tc = 25°C |
Gate Threshold Voltage | V(GSth) | - | 4 | 6 | V | I(D) = 1mA, Tc = 25°C |
Transconductance | gfs | - | 8 | - | S | V(DS) = 25V, I(D) = 1A, Tc = 25°C |
Input Capacitance | Ciss | - | 1700 | - | pF | f = 1MHz, V(DS) = 0V, V(GS) = 0V |
Output Capacitance | Coss | - | 300 | - | pF | f = 1MHz, V(DS) = 500V, V(GS) = 0V |
Reverse Transfer Capacitance | Crss | - | 30 | - | pF | f = 1MHz, V(DS) = 500V, V(GS) = 0V |
Total Power Dissipation | Ptot | - | 150 | - | W | Tc = 25°C |
Junction Temperature | Tj | - | - | 175 | °C | - |
Storage Temperature | Tstg | -55 | - | 150 | °C | - |
Instructions for Use:
Mounting:
- Ensure proper heat sinking to maintain junction temperature within safe limits.
- Use recommended mounting torque for screws to avoid damage.
Biasing:
- Apply gate-source voltage (V(GS)) carefully to avoid exceeding the maximum ratings.
- Ensure the gate threshold voltage (V(GSth)) is considered for proper turn-on and turn-off control.
Operation:
- Operate within the specified drain-source voltage (V(DS)) and drain current (I(D)) limits to prevent device failure.
- Monitor power dissipation (Ptot) to ensure it does not exceed the maximum allowable value.
Storage:
- Store in a dry environment within the storage temperature range (Tstg).
- Avoid exposure to high humidity and corrosive environments.
Handling:
- Handle with care to avoid mechanical stress on the leads and body.
- Use ESD (Electrostatic Discharge) precautions to prevent damage from static electricity.
Testing:
- Use appropriate test equipment and procedures to avoid overstressing the device during testing.
- Refer to the datasheet for specific test conditions and methods.
Applications:
- Suitable for high-power switching applications, including power supplies, motor control, and inverters.
- Ensure the device is used within its safe operating area (SOA) for reliable performance.