Specifications
SKU: 443587
IC 64K SERIAL FRAM
Parameter | Description | Value | Unit |
---|---|---|---|
Device Type | Non-Volatile Memory | 64 Kbit (8 K x 8) | - |
Operating Voltage | Supply Voltage Range | 1.7 to 5.5 | V |
Operating Temperature | Industrial Temperature Range | -40 to +85 | °C |
Data Retention | Data Retention at 25°C | 200 | Years |
Write Cycles | Endurance | 1,000,000 | Cycles |
Access Time | Typical Access Time | 5 | μs |
Standby Current | Maximum Standby Current | 1 | μA |
Active Current | Maximum Active Current | 3 | mA |
Package | Package Type | 8-pin SOIC, 8-pin TSSOP | - |
Communication Interface | I2C Interface | Standard Mode (100 kHz), Fast Mode (400 kHz) | - |
Write Protection | Hardware Write Protect | Pin (WP) | - |
Memory Organization | Memory Configuration | 8K x 8 | - |
Instructions for Use
Power Supply:
- Connect the VCC pin to the power supply within the specified voltage range (1.7V to 5.5V).
- Connect the GND pin to the ground.
I2C Communication:
- Connect the SDA (Serial Data) and SCL (Serial Clock) pins to the corresponding I2C lines on your microcontroller.
- Ensure pull-up resistors are connected to the SDA and SCL lines to VCC. Typical values are 4.7kΩ to 10kΩ.
Write Protection:
- To enable write protection, connect the WP (Write Protect) pin to VCC.
- To disable write protection, connect the WP pin to GND or leave it floating.
Addressing:
- The device has a 7-bit I2C address, which can be configured using the A0, A1, and A2 pins. Refer to the datasheet for specific address configurations.
Reading Data:
- Initiate a start condition on the I2C bus.
- Send the device address with the read bit set.
- Read the desired number of bytes from the memory.
- Send a stop condition to end the read operation.
Writing Data:
- Initiate a start condition on the I2C bus.
- Send the device address with the write bit set.
- Send the memory address where data will be written.
- Send the data to be written.
- Send a stop condition to end the write operation.
- Wait for the write cycle to complete before initiating another write operation. This typically takes 5 μs.
Data Retention:
- Ensure that the device is not exposed to excessive heat or radiation to maintain data retention over the specified period.
Handling:
- Handle the device with care to avoid static damage. Use proper ESD precautions.
Storage:
- Store the device in a dry, cool place to ensure long-term reliability.
For detailed timing diagrams and advanced features, refer to the FM24C64-P datasheet provided by the manufacturer.
(For reference only)Inquiry - FM24C64-P