Share:


TLP626

Specifications

SKU: 569944

BUY TLP626 https://www.utsource.net/itm/p/569944.html
AC Input-Transistor Output Optocoupler, 1-Element, 5300V Isolation, ROHS COMPLIANT, PLASTIC, DIP-4
Parameter Symbol Min Typ Max Unit Conditions
Forward Voltage VF - 1.2 1.5 V IF = 20 mA, Ta = 25°C
Peak Forward Current IF(P) - - 1 A A tP = 1 ms, Duty = 1/10
Continuous Forward Current IF - - 30 mA Ta = 25°C
Reverse Breakdown Voltage VBR 5 - 7 V IR = 10 μA, Ta = 25°C
Output Collector-Emitter Saturation Voltage VCE(sat) - 0.4 0.7 V IC = 10 mA, IF = 5 mA, Ta = 25°C
Output Collector Current IC - - 10 mA VCE = 5 V, IF = 5 mA, Ta = 25°C
Isolation Voltage VIORM - - 2500 Vrms 1 min, 50/60 Hz
Storage Temperature TSTG -40 - 100 °C -
Operating Temperature TA -40 - 85 °C -

Instructions for Use

  1. Mounting and Handling:

    • Handle the device with care to avoid mechanical damage.
    • Ensure proper mounting to prevent excessive stress on the leads.
  2. Electrical Connections:

    • Connect the input (anode and cathode) to the control circuit.
    • Connect the output (collector and emitter) to the load circuit.
    • Ensure all connections are secure and free from shorts or open circuits.
  3. Forward Current:

    • Do not exceed the maximum continuous forward current (IF) of 30 mA.
    • For peak conditions, do not exceed 1 A for a pulse duration of 1 ms with a duty cycle of 1/10.
  4. Reverse Voltage:

    • Ensure the reverse voltage does not exceed the reverse breakdown voltage (VBR) of 7 V to prevent damage.
  5. Output Current:

    • The maximum output collector current (IC) is 10 mA. Exceeding this can lead to device failure.
  6. Isolation Voltage:

    • The device provides isolation up to 2500 Vrms for 1 minute at 50/60 Hz. Ensure this is not exceeded to maintain safety and performance.
  7. Temperature Considerations:

    • The storage temperature range is -40°C to 100°C.
    • The operating temperature range is -40°C to 85°C. Ensure the device operates within these limits to avoid thermal damage.
  8. Testing and Verification:

    • Perform initial testing under controlled conditions to verify correct operation.
    • Regularly check for any signs of wear or damage and replace the device if necessary.
  9. Compliance and Standards:

    • Ensure the device complies with relevant safety and regulatory standards for your application.

By following these guidelines, you can ensure reliable and safe operation of the TLP626 optocoupler.