Share:


SN74192J

Specifications

SKU: 674464

BUY SN74192J https://www.utsource.net/itm/p/674464.html
SYNCHRONOUS 4-BIT UP/DOWN COUNTERS (DUAL CLOCK WITH CLEAR)
Parameter Description Min Typ Max Unit
VCC Supply Voltage 4.5 - 5.5 V
ICC Supply Current (Typical) - 20 - mA
fMAX Maximum Clock Frequency - - 20 MHz
tpd Propagation Delay Time 20 35 50 ns
tphl High-to-Low Output Delay 10 20 30 ns
tplh Low-to-High Output Delay 10 20 30 ns
IOH Output High Current -0.4 - - mA
IOL Output Low Current - - 8 mA
VIH Input High Voltage 2.0 - 5.5 V
VIL Input Low Voltage 0 - 0.8 V
VOH Output High Voltage 2.4 - 5.0 V
VOL Output Low Voltage 0 - 0.4 V

Instructions for Using SN74192J:

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the range of 4.5V to 5.5V.
    • Connect the ground (GND) pin to a stable ground reference.
  2. Clock Input (CP):

    • Apply the clock signal to the CP pin. The maximum frequency should not exceed 20 MHz.
  3. Control Inputs:

    • Use the control inputs (UP, DOWN, LOAD, and CLEAR) to control the operation of the counter.
      • UP: Set high to count up.
      • DOWN: Set high to count down.
      • LOAD: Set high to load the preset value from the data inputs.
      • CLEAR: Set high to reset the counter to zero.
  4. Data Inputs (A, B, C, D):

    • Connect these pins to the desired preset values when the LOAD input is high.
  5. Output (QA, QB, QC, QD):

    • These pins provide the binary output of the counter. They can be used to drive other logic circuits or displays.
  6. Propagation Delay:

    • Account for the propagation delay times (tpd, tphl, tplh) in your timing calculations to ensure proper synchronization.
  7. Current Limits:

    • Ensure that the output current does not exceed the specified limits (IOH and IOL) to avoid damage to the device.
  8. Operating Temperature:

    • The device is typically rated for operation over a temperature range of -40°C to +85°C. Ensure the operating environment stays within this range.
  9. Storage:

    • Store the device in a dry, cool place to prevent moisture damage.
  10. Handling:

    • Handle the device with care to avoid static discharge, which can damage the internal circuitry. Use appropriate ESD protection measures.
(For reference only)

 Inquiry - SN74192J