Share:


AD7568BSZ

Specifications

SKU: 702463

BUY AD7568BSZ https://www.utsource.net/itm/p/702463.html
The AD7568 contains eight 12-bit DACs in one monolithic device. The DACs are standard current output with seperate VREF, IOUT1, IOUT2 and RFB terminals. The AD7568 is a serial input device. Data is loaded using FSIN, CLKIN and SDIN. One address pin, A0, sets up a device address, and this feature may be used to simplify device loading in a multi-DAC environment. All DACs can be simultaneously updated using the asynchronous LDAC input, and they can be cleared by asserting the asynchronous CLR input. The AD7568 is housed in a space-saving 44-pin plastic quad flatback and 44-lead PLCC. APPLICATIONS Process Control Automatic Test Equipment General Purpose Instrumentation
Parameter Symbol Conditions Min Typical Max Unit
Supply Voltage VDD Operating Range 4.5 - 5.5 V
Digital Input Voltage VIH High Level 2.0 - 5.5 V
Digital Input Voltage VIL Low Level 0 - 0.8 V
Output Voltage Range VOH High Level - 5.0 5.0 V
Output Voltage Range VOL Low Level 0 0.0 0.1 V
Output Current IOUT Continuous - 10 10 mA
Power Dissipation PD Maximum - - 300 mW
Operating Temperature TA Commercial 0 - 70 °C
Operating Temperature TA Industrial -40 - 85 °C
Storage Temperature TSTG -65 - 150 °C
Input Capacitance CIN - 10 10 pF
Output Capacitance COUT - 100 100 pF
Settling Time tS 0.1% Accuracy - 10 15 μs
Differential Nonlinearity DNL Full Scale -1 0 +1 LSB
Integral Nonlinearity INL Full Scale -1 0 +1 LSB

Instructions for Use:

  1. Power Supply:

    • Ensure the supply voltage (VDD) is within the range of 4.5V to 5.5V.
    • Connect the power supply to the VDD pin and ground (GND) pin.
  2. Digital Inputs:

    • Digital input signals should be within the specified high (VIH) and low (VIL) levels.
    • Use appropriate logic levels to control the digital inputs.
  3. Output Configuration:

    • The output voltage range is from 0V to 5V.
    • Ensure the load resistance and capacitance are within the specified limits to avoid excessive power dissipation.
  4. Temperature Considerations:

    • For commercial applications, operate within 0°C to 70°C.
    • For industrial applications, operate within -40°C to 85°C.
    • Store the device within the storage temperature range of -65°C to 150°C.
  5. Performance Parameters:

    • Monitor differential nonlinearity (DNL) and integral nonlinearity (INL) to ensure accurate conversion.
    • Verify the settling time for the desired accuracy in your application.
  6. Handling and Storage:

    • Handle the device with care to avoid static damage.
    • Store in a dry environment to prevent moisture-related issues.
  7. Testing and Troubleshooting:

    • Test the device under typical operating conditions to ensure it meets the specified parameters.
    • If issues arise, check the power supply, digital inputs, and load conditions for any discrepancies.
(For reference only)

 Inquiry - AD7568BSZ