Specifications
SKU: 708982
Non-aliasing, 16- & 20-bit A/D Converters
Parameter | Description | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Supply Voltage (VDD) | Operating voltage range | 2.7 | - | 5.5 | V |
Supply Current | Quiescent current | - | 200 | - | μA |
Output Current | Maximum output current | - | - | 100 | mA |
Temperature Range | Operating temperature range | -40 | - | 85 | °C |
Conversion Time | Time required for one conversion | - | 10 | - | ms |
Resolution | ADC resolution | - | 12 | - | bits |
Input Range | Analog input voltage range | 0 | - | VDD | V |
Differential Inputs | Number of differential inputs | - | 3 | - | |
Single-Ended Inputs | Number of single-ended inputs | - | 6 | - | |
Reference Voltage | Internal reference voltage | 2.048 | - | 2.048 | V |
Power-down Mode | Current consumption in power-down mode | - | 0.1 | - | μA |
Output Data Rate | Maximum output data rate | - | 20 | - | SPS |
SPI Interface | Support for SPI interface | - | Yes | - |
Instructions
Power Supply:
- Ensure the supply voltage (VDD) is within the range of 2.7V to 5.5V.
- Connect the ground (GND) pin to a stable ground reference.
Analog Inputs:
- Connect analog signals to the differential or single-ended inputs within the range of 0V to VDD.
- Use the internal reference voltage of 2.048V for accurate measurements.
SPI Communication:
- Connect the SPI interface pins (MISO, MOSI, SCLK, CS) to the corresponding pins on your microcontroller.
- Set the chip select (CS) pin low to initiate communication.
- Use the SCLK pin to clock data in and out of the device.
Configuration:
- Configure the device using the SPI interface to set parameters such as input range, conversion time, and output data rate.
- Refer to the datasheet for specific configuration register settings.
Data Conversion:
- Initiate a conversion by writing to the appropriate register.
- Read the conversion result from the data register after the conversion is complete.
Power Management:
- To reduce power consumption, use the power-down mode by setting the appropriate bit in the configuration register.
- The device will consume approximately 0.1 μA in power-down mode.
Temperature Considerations:
- Ensure the operating temperature remains between -40°C and 85°C to maintain performance and reliability.
Output Current:
- Do not exceed the maximum output current of 100 mA to avoid damaging the device.
Handling Static Electricity:
- Handle the device with care to avoid damage from static electricity.
- Use proper ESD protection when handling the device.
Storage and Handling:
- Store the device in a dry, cool place away from direct sunlight.
- Follow recommended storage and handling guidelines to ensure long-term reliability.