Specifications
SKU: 758334
SMPS Controller
Parameter | Symbol | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Input Voltage | V_IN | 85 | - | 265 | VAC |
Output Voltage | V_OUT | 3.3 | 5.0 | 12 | VDC |
Output Current | I_OUT | - | 2.1 | - | A |
Switching Frequency | f_SW | 75 | - | 132 | kHz |
Efficiency | η | - | 86 | - | % |
Power Dissipation | P_DISS | - | 15 | - | W |
Operating Temperature | T_OP | -40 | - | 85 | °C |
Storage Temperature | T_STG | -55 | - | 125 | °C |
Humidity | RH | - | 95 | - | % |
Isolation Voltage | V_ISO | - | 3750 | - | VAC |
Leakage Current | I_LEAK | - | 10 | - | μA |
No-Load Power Consumption | P_NL | - | 0.15 | - | W |
Instructions for TOP244R-TL
Input Connection:
- Connect the input terminals to the AC power supply within the specified voltage range (85VAC to 265VAC).
Output Connection:
- Connect the output terminals to the load. Ensure the load does not exceed the maximum output current (2.1A).
Heat Dissipation:
- Mount the device on a heatsink to ensure proper heat dissipation, especially under high load conditions.
Operating Environment:
- Operate the device within the specified temperature range (-40°C to 85°C) and humidity range (up to 95% RH).
Isolation:
- Ensure that the isolation voltage (3750VAC) is maintained between the input and output circuits to prevent electrical shock.
No-Load Operation:
- The device has a low no-load power consumption (0.15W), making it suitable for applications where standby power is a concern.
Leakage Current:
- The leakage current is typically 10μA. Ensure this is within acceptable limits for your application.
Storage:
- Store the device in a dry environment within the storage temperature range (-55°C to 125°C).
Safety Precautions:
- Follow all safety guidelines and regulations when handling and installing the device.
- Use appropriate fuses and protection circuits to safeguard against overvoltage and short circuits.
Inquiry - TOP244R-TL