Single Phase 3.0 AMPS. Glass Passivated Bridge Rectifiers
Parameter Symbol Min Typ Max Unit Description
Input Voltage V_IN 2.7 - 5.5 V Operating input voltage range
Output Voltage V_OUT - 3.3 - V Fixed output voltage
Output Current I_OUT - 300 - mA Maximum continuous output current
Quiescent Current I_Q - 1.0 - μA Typical quiescent current
Dropout Voltage V_DROPOUT - 0.3 - V Typical dropout voltage at I_OUT = 300mA
Load Regulation - - 1% - % Load regulation from 0 to 300mA
Line Regulation - - 1% - % Line regulation over input range
Ripple Rejection - - 60 - dB Typical ripple rejection at 1kHz
Operating Temp T_OP -40 - 85 °C Operating temperature range
Storage Temp T_STG -65 - 150 °C Storage temperature range

Instructions for Use:

  1. Input Connection:

    • Connect the input voltage (V_IN) to the input pin of the KBP307.
    • Ensure the input voltage is within the specified range of 2.7V to 5.5V.
  2. Output Connection:

    • Connect the output pin of the KBP307 to the load or circuit requiring a regulated 3.3V supply.
    • The maximum output current is 300mA.
  3. Ground Connection:

    • Connect the ground (GND) pin to the common ground of the system.
  4. Capacitors:

    • Place a 1μF ceramic capacitor between the input pin and ground to filter input noise.
    • Place a 1μF ceramic capacitor between the output pin and ground to stabilize the output voltage.
  5. Thermal Considerations:

    • Ensure adequate heat dissipation if operating near the maximum output current, especially at higher ambient temperatures.
    • The device can operate up to 85°C, but performance may degrade at higher temperatures.
  6. Storage:

    • Store the KBP307 in a dry environment within the temperature range of -65°C to 150°C.
  7. Handling:

    • Handle with care to avoid static damage. Use appropriate ESD protection measures.
  8. Testing:

    • Before finalizing the design, test the regulator under various load conditions to ensure stability and performance meet the requirements.