Specifications
SKU: 780807
Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
---|---|---|---|---|---|---|
Supply Voltage | VCC | 2.0 | 4.5 | 6.0 | V | |
Input Voltage (High) | VIH | - | 3.15 | - | V | VCC = 4.5V |
Input Voltage (Low) | VIL | - | 1.35 | - | V | VCC = 4.5V |
Output Voltage (High) | VOH | 2.4 | 3.6 | - | V | IO = -4mA, VCC = 4.5V |
Output Voltage (Low) | VOL | - | 0.4 | 0.55 | V | IO = 4mA, VCC = 4.5V |
Input Current (High) | IIH | - | 1 | 20 | μA | VI = VCC - 1.5V |
Input Current (Low) | IIL | - | -1 | -20 | μA | VI = 0.8V |
Output Current (High) | IOH | - | -4 | -10 | mA | VOH = 2.4V, VCC = 4.5V |
Output Current (Low) | IOL | - | 4 | 10 | mA | VOL = 0.4V, VCC = 4.5V |
Propagation Delay Time | tpd | 5 | 10 | 18 | ns | VCC = 4.5V, fCLK = 10MHz |
Power Dissipation | PD | - | - | 100 | mW | Per Package |
Operating Temperature | TA | -40 | - | 85 | °C |
Instructions for Using 74HC299D
Power Supply:
- Connect VCC to the positive supply voltage (2.0V to 6.0V).
- Connect GND to the ground.
Input Signals:
- Ensure that input signals (e.g., data, clock, control signals) are within the valid range:
- High level: VIH > 3.15V (for VCC = 4.5V)
- Low level: VIL < 1.35V (for VCC = 4.5V)
- Ensure that input signals (e.g., data, clock, control signals) are within the valid range:
Output Signals:
- Ensure that output loads do not exceed the maximum output current ratings:
- High level: IOH ≤ -4mA
- Low level: IOL ≤ 4mA
- Ensure that output loads do not exceed the maximum output current ratings:
Clock Signal:
- The 74HC299D operates with a clock signal (fCLK). Ensure the clock frequency is within the specified range to avoid timing issues.
Control Inputs:
- Use the control inputs (e.g., S1, S2, S3) to configure the operation mode (shift register, parallel load, etc.).
Data Handling:
- Data can be shifted into the register on the rising edge of the clock signal.
- Data can be shifted out or loaded in parallel based on the control signals.
Power Dissipation:
- Ensure that the total power dissipation does not exceed 100mW to prevent overheating.
Temperature Range:
- Operate the device within the specified temperature range (-40°C to 85°C) to ensure reliable performance.
Storage and Handling:
- Store the device in a dry environment and handle with care to avoid static damage.
Testing:
- Test the device under typical operating conditions to verify its functionality before integrating it into a larger system.
Inquiry - 74HC299D