Specifications
SKU: 822557
Axial Lead Standard Recovery Rectifiers
Parameter | Value | Unit |
---|---|---|
Type | General Purpose Diode | |
Maximum Repetitive Peak Reverse Voltage (VRRM) | 600 | V |
Maximum Average Forward Rectified Current (IF(AV)) | 1 | A |
Peak Surge Current (IFSM) | 30 | A |
Maximum Operating Junction Temperature (TJ(MAX)) | 150 | °C |
Forward Voltage Drop (VF) at IF = 1A | 1.1 | V |
Reverse Recovery Time (trr) | 35 | μs |
Thermal Resistance, Junction to Case (RθJC) | 25 | °C/W |
Package | DO-41 (Axial Lead) | |
Mounting Position | Any |
Instructions for Use:
Handling:
- Handle the diode with care to avoid mechanical stress.
- Avoid touching the leads or body with bare hands to prevent static damage.
Soldering:
- Preheat the diode to 70°C to 90°C before soldering.
- Solder within 3 seconds at a temperature not exceeding 260°C.
- Allow the diode to cool naturally after soldering.
Mounting:
- Ensure proper heat dissipation by mounting the diode on a heatsink if operating near maximum current or temperature.
- Use appropriate clamping or securing methods to prevent mechanical strain on the leads.
Electrical Connections:
- Connect the anode (longer lead) to the positive side of the circuit.
- Connect the cathode (shorter lead, marked with a band) to the negative side of the circuit.
Storage:
- Store in a dry, cool place away from direct sunlight.
- Keep in original packaging until ready for use to protect against static discharge.
Testing:
- Use a multimeter to test the diode for continuity.
- The diode should show a low resistance in one direction and high resistance in the reverse direction.