Share:


ILD223T

Specifications

SKU: 904087

BUY ILD223T https://www.utsource.net/itm/p/904087.html
IC OPTOCOUPLER DUAL SO8
Parameter Symbol Min Typ Max Unit Description
Input Voltage VIN 4.5 - 60 V Operating input voltage range
Output Voltage VOUT - 3.3 - V Fixed output voltage
Output Current IOUT - 3 3.5 A Continuous output current
Quiescent Current IQ 10 20 30 μA Quiescent current at no load
Dropout Voltage VDO - 1.2 - V Dropout voltage at IOUT = 3A
Efficiency η - 95 - % Typical efficiency at full load
Thermal Shutdown TSD - 160 - °C Thermal shutdown temperature
Operating Temperature TA -40 - 125 °C Ambient operating temperature range
Storage Temperature TSTG -40 - 150 °C Storage temperature range

Instructions for Use

  1. Input Connection:

    • Connect the input voltage (VIN) to the VIN pin.
    • Ensure the input voltage is within the specified range (4.5V to 60V).
  2. Output Connection:

    • Connect the output load to the VOUT pin.
    • The output voltage is fixed at 3.3V and can supply up to 3.5A.
  3. Ground Connection:

    • Connect the ground (GND) pin to the common ground of your circuit.
  4. Capacitors:

    • Place a 1μF ceramic capacitor close to the VIN pin for input filtering.
    • Place a 1μF ceramic capacitor close to the VOUT pin for output filtering.
  5. Thermal Management:

    • Ensure adequate heat dissipation, especially when operating at high currents.
    • Use a heatsink if necessary to keep the device temperature below 160°C.
  6. Protection:

    • The device includes thermal shutdown protection to prevent damage from overheating.
    • Avoid continuous operation at or near the maximum operating temperature.
  7. Storage:

    • Store the device in a dry environment within the temperature range of -40°C to 150°C.
  8. Handling:

    • Handle with care to avoid static discharge and physical damage.
    • Follow standard ESD (Electrostatic Discharge) precautions.
(For reference only)

 Inquiry - ILD223T