Share:


TDA2010

Specifications

SKU: 972569

BUY TDA2010 https://www.utsource.net/itm/p/972569.html

Parameter Symbol Value Unit
Supply Voltage Vcc 4.5 to 22 V
Quiescent Current Iq 10 mA
Output Power (8Ω) Pout 4.5 W
Total Harmonic Distortion THD 0.5 %
Frequency Response f 10 Hz to 70 kHz
Signal-to-Noise Ratio SNR 80 dB
Input Sensitivity Vin 200 mV
Maximum Input Voltage Vin(max) 1.4 V
Gain Av 34 dB
Protection - Overload, short-circuit, thermal -

Instructions for Using TDA2010:

  1. Power Supply:

    • Connect the positive terminal of the power supply to pin 6 (Vcc) and the negative terminal to pin 4 (GND).
    • Ensure the supply voltage is within the range of 4.5V to 22V.
  2. Input Connection:

    • Connect the audio signal to pin 1 (In+).
    • Connect the ground of the audio signal to pin 4 (GND).
  3. Output Connection:

    • Connect the speaker to pin 5 (Out).
    • Ensure the speaker impedance is 8Ω for optimal performance.
  4. Biasing:

    • The internal biasing circuitry ensures proper operation under most conditions. No external biasing components are typically required.
  5. Thermal Management:

    • Mount the TDA2010 on a heatsink if operating at high power levels or in high ambient temperatures to prevent overheating.
  6. Protection:

    • The TDA2010 has built-in protection against overload, short-circuit, and thermal issues. However, it is recommended to use appropriate fuses and other protective measures in the power supply line.
  7. Capacitors:

    • Use a 100nF capacitor between pins 6 (Vcc) and 4 (GND) to filter out any noise from the power supply.
    • A 10μF electrolytic capacitor can be placed in parallel with the 100nF capacitor for additional filtering.
  8. Volume Control:

    • If a volume control is needed, place a potentiometer between the audio source and pin 1 (In+).
  9. Testing:

    • After assembly, apply the power supply and check for correct operation by connecting an audio source and a speaker. Adjust the volume as necessary.
  10. Storage:

    • Store the TDA2010 in a dry, cool place away from static electricity and corrosive environments.
(For reference only)

 Inquiry - TDA2010