Specifications
SKU: 1084968
16-Bit 100 kSPS Sampling ADC
Parameter | Symbol | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Supply Voltage | VDD | 4.5 | 5 | 5.5 | V |
Supply Current | IDD | - | 3 | - | mA |
Input Voltage Range | VIN | 0 | - | VDD | V |
Differential Input | VDIFF | -1 | - | 1 | V |
Common-Mode Input | VCM | 0 | - | VDD | V |
Output Voltage Range | VOUT | 0 | - | VDD | V |
Conversion Time | tCONV | - | 13 | - | μs |
Resolution | RES | - | 16 | - | bits |
Differential Nonlinearity | DNL | -1 | 0 | +1 | LSB |
Integral Nonlinearity | INL | -2 | 0 | +2 | LSB |
Signal-to-Noise Ratio | SNR | - | 90 | - | dB |
Total Harmonic Distortion | THD | - | -85 | - | dB |
Power-Down Mode Current | IDD(PD) | - | 1 | - | μA |
Operating Temperature | Toper | -40 | - | 85 | °C |
Storage Temperature | Tstg | -65 | - | 150 | °C |
Instructions for Using AD676KD
Power Supply:
- Connect the supply voltage (VDD) to a stable 5V source.
- Ensure the supply current (IDD) does not exceed 3mA.
Input Configuration:
- The input voltage range (VIN) should be between 0V and VDD.
- For differential inputs, ensure the differential input voltage (VDIFF) is within ±1V.
- The common-mode input voltage (VCM) should be within the range of 0V to VDD.
Output Configuration:
- The output voltage range (VOUT) will be between 0V and VDD.
- Ensure the load connected to the output can handle the output voltage range.
Conversion Time:
- The typical conversion time (tCONV) is 13μs. Ensure your system allows for this time before reading the output.
Resolution:
- The AD676KD provides a 16-bit resolution. Use the appropriate data format for 16-bit ADC outputs.
Linearity:
- The differential nonlinearity (DNL) and integral nonlinearity (INL) are specified to ensure accurate conversions. Check these parameters if high precision is required.
Signal-to-Noise Ratio (SNR) and Total Harmonic Distortion (THD):
- The SNR is typically 90dB, and THD is typically -85dB. These values indicate the quality of the analog-to-digital conversion.
Power-Down Mode:
- To reduce power consumption, use the power-down mode. In this mode, the supply current (IDD(PD)) drops to approximately 1μA.
Temperature Considerations:
- The operating temperature range (Toper) is from -40°C to 85°C.
- The storage temperature range (Tstg) is from -65°C to 150°C. Ensure the device is stored within these limits to avoid damage.
Handling and Installation:
- Handle the AD676KD with care to avoid static damage.
- Follow proper soldering techniques to ensure reliable connections.
By following these parameters and instructions, you can effectively integrate the AD676KD into your analog-to-digital conversion applications.
(For reference only)Inquiry - AD676KD