Share:


AD676KD

Specifications

SKU: 1084968

BUY AD676KD https://www.utsource.net/itm/p/1084968.html
16-Bit 100 kSPS Sampling ADC
Parameter Symbol Min Typ Max Unit
Supply Voltage VDD 4.5 5 5.5 V
Supply Current IDD - 3 - mA
Input Voltage Range VIN 0 - VDD V
Differential Input VDIFF -1 - 1 V
Common-Mode Input VCM 0 - VDD V
Output Voltage Range VOUT 0 - VDD V
Conversion Time tCONV - 13 - μs
Resolution RES - 16 - bits
Differential Nonlinearity DNL -1 0 +1 LSB
Integral Nonlinearity INL -2 0 +2 LSB
Signal-to-Noise Ratio SNR - 90 - dB
Total Harmonic Distortion THD - -85 - dB
Power-Down Mode Current IDD(PD) - 1 - μA
Operating Temperature Toper -40 - 85 °C
Storage Temperature Tstg -65 - 150 °C

Instructions for Using AD676KD

  1. Power Supply:

    • Connect the supply voltage (VDD) to a stable 5V source.
    • Ensure the supply current (IDD) does not exceed 3mA.
  2. Input Configuration:

    • The input voltage range (VIN) should be between 0V and VDD.
    • For differential inputs, ensure the differential input voltage (VDIFF) is within ±1V.
    • The common-mode input voltage (VCM) should be within the range of 0V to VDD.
  3. Output Configuration:

    • The output voltage range (VOUT) will be between 0V and VDD.
    • Ensure the load connected to the output can handle the output voltage range.
  4. Conversion Time:

    • The typical conversion time (tCONV) is 13μs. Ensure your system allows for this time before reading the output.
  5. Resolution:

    • The AD676KD provides a 16-bit resolution. Use the appropriate data format for 16-bit ADC outputs.
  6. Linearity:

    • The differential nonlinearity (DNL) and integral nonlinearity (INL) are specified to ensure accurate conversions. Check these parameters if high precision is required.
  7. Signal-to-Noise Ratio (SNR) and Total Harmonic Distortion (THD):

    • The SNR is typically 90dB, and THD is typically -85dB. These values indicate the quality of the analog-to-digital conversion.
  8. Power-Down Mode:

    • To reduce power consumption, use the power-down mode. In this mode, the supply current (IDD(PD)) drops to approximately 1μA.
  9. Temperature Considerations:

    • The operating temperature range (Toper) is from -40°C to 85°C.
    • The storage temperature range (Tstg) is from -65°C to 150°C. Ensure the device is stored within these limits to avoid damage.
  10. Handling and Installation:

    • Handle the AD676KD with care to avoid static damage.
    • Follow proper soldering techniques to ensure reliable connections.

By following these parameters and instructions, you can effectively integrate the AD676KD into your analog-to-digital conversion applications.

(For reference only)

 Inquiry - AD676KD