Share:


LT1129IST-5.0

Specifications

SKU: 1098002

BUY LT1129IST-5.0 https://www.utsource.net/itm/p/1098002.html
Micropower Low Dropout Regulators with Shutdown
Parameter Symbol Conditions Min Typ Max Unit
Input Voltage VIN Continuous 2.7 - 40 V
Output Voltage VOUT Fixed - 5.0 - V
Output Current IOUT Continuous - 1.0 - A
Quiescent Current IQ VIN = 12V, VOUT = 5V - 3.0 - mA
Dropout Voltage VDROPOUT IOUT = 1.0A, VIN = 5.5V - 0.5 - V
Load Regulation - 0mA to 1.0A - 0.1 - %
Line Regulation - 4.5V to 40V - 0.1 - %
Thermal Shutdown TSD - - 160 - °C
Operating Temperature TOPR - -40 - 125 °C
Storage Temperature TSTG - -65 - 150 °C

Instructions for Use:

  1. Input Voltage (VIN):

    • Ensure the input voltage is within the range of 2.7V to 40V.
    • Avoid exceeding the maximum input voltage to prevent damage to the device.
  2. Output Voltage (VOUT):

    • The LT1129IST-5.0 provides a fixed output voltage of 5.0V.
    • No external resistors are needed to set the output voltage.
  3. Output Current (IOUT):

    • The device can supply up to 1.0A of continuous current.
    • Ensure that the load does not exceed this limit to avoid overheating or damage.
  4. Quiescent Current (IQ):

    • The quiescent current is typically 3.0mA at 12V input and 5V output.
    • This current is drawn by the regulator itself and is independent of the load.
  5. Dropout Voltage (VDROPOUT):

    • The dropout voltage is typically 0.5V when the output current is 1.0A and the input voltage is 5.5V.
    • Ensure that the input voltage is at least 0.5V higher than the output voltage to maintain regulation.
  6. Load Regulation:

    • The load regulation is typically 0.1% over the load range from 0mA to 1.0A.
    • This indicates the stability of the output voltage with varying loads.
  7. Line Regulation:

    • The line regulation is typically 0.1% over the input voltage range from 4.5V to 40V.
    • This indicates the stability of the output voltage with varying input voltages.
  8. Thermal Shutdown (TSD):

    • The device will shut down if the junction temperature exceeds 160°C.
    • Ensure adequate heat sinking to prevent thermal shutdown.
  9. Operating Temperature (TOPR):

    • The operating temperature range is from -40°C to 125°C.
    • Ensure that the device operates within this range to avoid performance degradation or failure.
  10. Storage Temperature (TSTG):

    • The storage temperature range is from -65°C to 150°C.
    • Store the device in a dry environment within this temperature range to prevent damage.

Additional Notes:

  • Capacitors:

    • Use appropriate input and output capacitors to ensure stability and reduce ripple.
    • Recommended values are typically 1μF to 10μF ceramic capacitors for both input and output.
  • PCB Layout:

    • Ensure proper PCB layout to minimize noise and improve thermal performance.
    • Place the input and output capacitors as close as possible to the regulator.
  • Heat Sinking:

    • For high current applications, consider using a heatsink to dissipate heat effectively.
    • The thermal resistance (θJA) of the device should be considered in the design.

By following these guidelines, you can ensure reliable operation of the LT1129IST-5.0 in your application.

(For reference only)

 Inquiry - LT1129IST-5.0