Specifications
SKU: 1178300
Quad 2-Input NAND Buffered B Series Gate; Package: DIP; No of Pins: 14; Container: Rail
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Supply Voltage | VDD | - | 3 | 15 | 18 | V |
Input Low Voltage | VIL | - | 0 | 1.5 | - | V |
Input High Voltage | VIH | - | - | 3.5 | VDD | V |
Output Low Voltage | VOL | IOL = 4 mA | 0 | 0.4 | - | V |
Output High Voltage | VOH | IOH = -0.4 mA | - | VDD - 0.1 | VDD | V |
Input Leakage Current | IIL | VDD = 5 V | -1 | - | 1 | μA |
Output Leakage Current | IOL | VDD = 5 V, VO = 0 V | -20 | - | 20 | μA |
Propagation Delay Time | tpd | VDD = 5 V, VOH = 3.5 V, VOL = 0.5 V | - | 70 | - | ns |
Power Dissipation | PD | - | - | 100 | - | mW |
Instructions for Use
Supply Voltage (VDD):
- The CD4011BCN can operate with a supply voltage ranging from 3V to 18V. Ensure that the supply voltage is within this range to avoid damage to the device.
Input Voltage Levels (VIL, VIH):
- For an input to be recognized as low (VIL), it should be less than 1.5V.
- For an input to be recognized as high (VIH), it should be greater than 3.5V when VDD is at its maximum value.
Output Voltage Levels (VOL, VOH):
- When the output is low (VOL), it will be less than 0.4V under a load current of 4mA.
- When the output is high (VOH), it will be at least VDD - 0.1V under a load current of -0.4mA.
Leakage Currents (IIL, IOL):
- The input leakage current (IIL) is typically ±1μA at 5V.
- The output leakage current (IOL) is typically ±20μA at 5V and 0V output.
Propagation Delay Time (tpd):
- The propagation delay time is the time it takes for a change in input to affect the output. At 5V, it is typically 70ns.
Power Dissipation (PD):
- The maximum power dissipation is 100mW. Ensure that the device does not exceed this limit to prevent overheating and potential failure.
Handling Precautions:
- The CD4011BCN is sensitive to electrostatic discharge (ESD). Handle the device with care and use proper ESD protection measures.
- Avoid connecting inputs or outputs to voltages outside the specified range.
- Ensure that all power and ground connections are secure and stable.
Storage and Operating Temperature:
- Store the device in a dry environment to prevent moisture damage.
- The operating temperature range is typically -40°C to +85°C. Ensure that the device operates within this range to maintain reliability.