Specifications
SKU: 1374653
FM/AM Radio
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Input Voltage | VIN | 4.5 | - | 28 | V | Operating input voltage range |
Output Voltage | VOUT | 0.8 | - | 20 | V | Adjustable output voltage range |
Output Current | IOUT | - | - | 3 | A | Maximum continuous output current |
Quiescent Current | IQ | - | 2.5 | 6 | mA | Quiescent current at no load |
Dropout Voltage | VDROPOUT | - | 1.2 | 2 | V | Typical dropout voltage at 3A |
Load Regulation | - | - | 0.1 | 0.5 | % | Change in output voltage with load |
Line Regulation | - | - | 0.1 | 0.5 | % | Change in output voltage with input voltage |
Ripple Rejection | - | 60 | 70 | 80 | dB | PSRR at 100 kHz |
Operating Temp | Toper | -40 | - | 125 | °C | Operating temperature range |
Storage Temp | Tstg | -65 | - | 150 | °C | Storage temperature range |
Instructions for Use:
Input Connection:
- Connect the input voltage (VIN) to the positive terminal of the CXA1019.
- Ensure the input voltage is within the specified range (4.5V to 28V).
Output Connection:
- Connect the output voltage (VOUT) to the load.
- Adjust the output voltage using the external resistor network if necessary.
Ground Connection:
- Connect the ground (GND) pin to the common ground of the system.
Capacitors:
- Place a 10μF ceramic capacitor between VIN and GND close to the CXA1019 to stabilize the input.
- Place a 10μF ceramic capacitor between VOUT and GND to stabilize the output.
Thermal Considerations:
- Ensure adequate heat dissipation, especially when operating at high output currents.
- Use a heatsink if necessary to keep the junction temperature within the operating range.
Protection:
- The CXA1019 includes overcurrent and thermal protection.
- Do not exceed the maximum output current or operating temperature to avoid damage.
Adjusting Output Voltage:
- Use the formula ( V_ = 1.23 left(1 + fracright) ) to set the desired output voltage.
- Choose appropriate values for R1 and R2 to achieve the desired VOUT.
Testing:
- Before connecting the load, verify the output voltage with a multimeter.
- Gradually increase the load to ensure stable operation.
Storage:
- Store the CXA1019 in a dry, cool place within the storage temperature range (-65°C to 150°C).
Handling:
- Handle the CXA1019 with care to avoid static discharge.
- Follow standard ESD precautions during assembly and testing.
Inquiry - CXA1019