Share:


UC3833N

Specifications

SKU: 1386371

BUY UC3833N https://www.utsource.net/itm/p/1386371.html
Rad-hard hex buffer/converter inverter
Parameter Symbol Min Typ Max Unit Description
Supply Voltage Vcc 4.5 12 36 V Operating voltage range
Start-Up Current Istartup - 100 - μA Current required to start the device
Quiescent Current Iq - 3 - mA Current consumed by the device in quiescent state
Shutdown Current Ishutdown - 1 - μA Current consumed by the device in shutdown mode
Reference Voltage Vref 4.95 5.0 5.05 V Voltage reference output
Oscillator Frequency Range fosc 0.1 - 1.0 MHz Range of oscillator frequency
Dead Time Tdead 0.1 0.2 0.3 μs Minimum time between the turn-off of one switch and the turn-on of the other
Maximum Duty Cycle Dmax - 95 - % Maximum duty cycle of the PWM output
Output Current Iout 100 300 500 mA Maximum current the output can source or sink
Thermal Shutdown Temperature Tsd 150 - 170 °C Temperature at which the device will shut down to prevent damage

Instructions for Using the UC3833N:

  1. Power Supply:

    • Ensure the supply voltage (Vcc) is within the specified range of 4.5V to 36V.
    • Use a stable power supply to avoid fluctuations that could affect performance.
  2. Start-Up and Quiescent Current:

    • The device requires a minimum startup current of 100 μA to begin operation.
    • In quiescent mode, the device consumes approximately 3 mA of current.
  3. Shutdown Mode:

    • To place the device in shutdown mode, pull the shutdown pin low. The device will consume about 1 μA of current in this mode.
  4. Reference Voltage:

    • The reference voltage (Vref) is typically 5.0V with a tolerance of ±0.05V. This voltage can be used as a stable reference for external circuits.
  5. Oscillator Frequency:

    • Set the oscillator frequency using an external resistor and capacitor. The frequency range is from 0.1 MHz to 1.0 MHz.
  6. Dead Time:

    • Ensure a dead time of at least 0.1 μs to 0.3 μs between the turn-off of one switch and the turn-on of the other to prevent shoot-through currents.
  7. Duty Cycle:

    • The maximum duty cycle is 95%. Avoid exceeding this limit to maintain reliable operation.
  8. Output Current:

    • The device can source or sink up to 500 mA of current. Ensure the load does not exceed this limit to prevent damage.
  9. Thermal Management:

    • Monitor the temperature of the device. If it exceeds 150°C, the device will enter thermal shutdown to protect itself. Ensure adequate cooling to keep the temperature below this threshold.
  10. Layout Considerations:

    • Use short, wide traces for power and ground connections to minimize inductance and improve stability.
    • Place decoupling capacitors close to the Vcc and GND pins to filter out noise and ensure stable operation.
  11. Protection Circuits:

    • Implement appropriate protection circuits such as overvoltage, undervoltage, and overcurrent protection to safeguard the device and connected components.

By following these instructions, you can ensure optimal performance and reliability of the UC3833N in your application.