Specifications
SKU: 1466892
INSTOCK
Parameter | Symbol | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Drain-Source Voltage | V(DS) | - | - | 400 | V |
Gate-Source Voltage | V(GS) | -20 | - | 10 | V |
Drain Current (Continuous) | I(D) | - | 10 | 15 | A |
Drain Current (Pulse) | I(DM) | - | - | 30 | A |
Power Dissipation | P(TOT) | - | - | 180 | W |
Junction Temperature | T(J) | -55 | - | 150 | °C |
Storage Temperature | T(STG) | -55 | - | 150 | °C |
Thermal Resistance (J-C) | R(THJC) | - | 1.0 | - | °C/W |
Instructions for Use:
Handling Precautions:
- Handle the 2SK1544 with care to avoid damage to the leads or the body.
- Use proper ESD (Electrostatic Discharge) protection when handling the device to prevent damage from static electricity.
Mounting:
- Ensure that the mounting surface is clean and flat.
- Apply thermal compound between the device and the heatsink to improve heat dissipation.
- Tighten the mounting screws to the recommended torque to ensure good thermal contact without damaging the device.
Biasing:
- Apply the gate-source voltage (V(GS)) within the specified range to control the drain current (I(D)).
- Ensure that the gate-source voltage does not exceed the maximum rating to avoid damaging the device.
Operation:
- Operate the device within the specified drain-source voltage (V(DS)) and drain current (I(D)) limits.
- Monitor the junction temperature (T(J)) to ensure it does not exceed the maximum rating. Use appropriate cooling methods such as heatsinks or fans if necessary.
Storage:
- Store the device in a dry, cool place away from direct sunlight and sources of heat.
- Keep the device in its original packaging until ready for use to protect it from environmental factors.
Testing:
- Use a suitable test setup to verify the electrical parameters of the device.
- Follow standard testing procedures to ensure accurate measurements and avoid damage to the device.
Safety:
- Always follow safety guidelines when working with high voltages and currents.
- Use appropriate personal protective equipment (PPE) and ensure that the work area is well-ventilated.
Inquiry - 2SK1544