Share:


DG200ABA

Specifications

SKU: 1467652

BUY DG200ABA https://www.utsource.net/itm/p/1467652.html
IC SWITCH SPST DUAL TO100-10

Below is the parameter table and instructions for the DG200ABA, a digital isolator from Texas Instruments.

DG200ABA Parameter Table

Parameter Symbol Min Typ Max Unit Conditions
Supply Voltage (Input Side) VDD1 3.0 5.0 5.5 V
Supply Voltage (Output Side) VDD2 3.0 5.0 5.5 V
Input High Voltage VIH 2.0 - VDD1 V
Input Low Voltage VIL 0 - 0.8 V
Output High Voltage VOH 2.4 - VDD2-0.4 V IOH = -4 mA
Output Low Voltage VOL 0 - 0.4 V IOL = 4 mA
Propagation Delay (High to Low) tPLH 10 25 50 ns VDD1 = VDD2 = 5V, fIN = 1 MHz
Propagation Delay (Low to High) tPHL 10 25 50 ns VDD1 = VDD2 = 5V, fIN = 1 MHz
Maximum Data Rate fMAX - - 100 Mbps
Isolation Voltage VIORM - - 2500 Vrms 1 minute
Operating Temperature Range Toperating -40 - 125 °C
Storage Temperature Range Tstorage -65 - 150 °C

Instructions for Using the DG200ABA

  1. Power Supply Connection:

    • Connect VDD1 to the power supply on the input side.
    • Connect VDD2 to the power supply on the output side.
    • Ensure both VDD1 and VDD2 are within the specified range (3.0V to 5.5V).
  2. Signal Input:

    • Connect the digital signal to be isolated to the input pin (IN).
    • The input signal should be within the valid logic levels defined by VIH and VIL.
  3. Signal Output:

    • The isolated output signal will be available at the output pin (OUT).
    • Ensure the load connected to the output pin is within the specified current limits (IOH and IOL).
  4. Propagation Delay:

    • The propagation delay (tPLH and tPHL) should be considered when designing the system to ensure proper timing.
    • For best performance, keep the propagation delay within the typical range (25 ns).
  5. Isolation:

    • The DG200ABA provides galvanic isolation up to 2500 Vrms for 1 minute.
    • Ensure that the isolation barrier is not exceeded to avoid damage to the device.
  6. Operating and Storage Conditions:

    • Operate the device within the specified temperature range (-40°C to 125°C).
    • Store the device within the storage temperature range (-65°C to 150°C).
  7. Handling Precautions:

    • Handle the device with care to avoid static discharge.
    • Follow standard ESD (Electrostatic Discharge) precautions when handling the device.

By following these parameters and instructions, you can effectively use the DG200ABA in your digital isolation applications.

(For reference only)