Specifications
SKU: 1469354
Low Drop Voltage Tracker
Parameter | Symbol | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Supply Voltage | VCC | 3.0 | 5.0 | 30.0 | V |
Output Current (Sink) | ISINK | - | 100 | - | mA |
Output Current (Source) | ISOURCE | - | 50 | - | mA |
Operating Temperature | TOP | -40 | - | 150 | °C |
Storage Temperature | TSTORAGE | -65 | - | 150 | °C |
Quiescent Current | IQ | - | 0.8 | - | mA |
Output Low Voltage | VOL | - | 0.4 | - | V |
Output High Voltage | VOH | - | 4.5 | - | V |
Response Time | tR | - | 2 | - | μs |
Instructions for Use:
Power Supply:
- Ensure the supply voltage is within the range of 3.0V to 30.0V.
- Connect the VCC pin to the power supply and GND to the ground.
Output Configuration:
- The device can sink up to 100mA and source up to 50mA.
- Connect the load between the output pin and the appropriate power rail (GND for sinking, VCC for sourcing).
Temperature Considerations:
- Operate the device within the temperature range of -40°C to 150°C.
- Store the device within the temperature range of -65°C to 150°C.
Quiescent Current:
- The quiescent current is typically 0.8mA. This should be considered in low-power applications.
Output Levels:
- The output low voltage (VOL) is typically 0.4V.
- The output high voltage (VOH) is typically 4.5V when the supply voltage is 5V.
Response Time:
- The typical response time is 2μs. This is important for applications requiring fast switching.
Handling Precautions:
- Handle the device with care to avoid static damage.
- Follow proper soldering techniques to ensure reliable connections.