Share:


74HC7266D

Specifications

SKU: 1559595

BUY 74HC7266D https://www.utsource.net/itm/p/1559595.html

Parameter Description Min Typ Max Unit
VCC Supply Voltage 2.0 - 6.0 V
ICC Supply Current (Quiescent) - 1.0 - μA (Note 1)
VIH Input High Voltage 3.15 - VCC V
VIL Input Low Voltage 0 - 0.85 V
VOH Output High Voltage 2.4 - VCC - 0.1 V
VOL Output Low Voltage 0 - 0.1 V
IOH Output High Current - - -4 mA
IOL Output Low Current -16 - - mA
tpd Propagation Delay Time 0 10 20 ns (Note 2)
tr Rise Time 0 5 10 ns (Note 2)
tf Fall Time 0 5 10 ns (Note 2)
tsu Setup Time 0 10 20 ns (Note 2)
th Hold Time 0 5 10 ns (Note 2)

Notes:

  1. Quiescent Current (ICC): The typical value is given at VCC = 4.5V and TA = 25°C.
  2. Timing Parameters: All timing parameters are specified at VCC = 4.5V, TA = 25°C, and with standard test conditions.

Instructions for Use:

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the range of 2.0V to 6.0V.
    • Connect the ground (GND) pin to a stable reference ground.
  2. Input Signals:

    • Apply input signals that meet the VIH and VIL specifications.
    • Avoid applying voltages outside the VCC range to the input pins.
  3. Output Signals:

    • Ensure the output load does not exceed the maximum output current ratings (IOH and IOL).
    • Use appropriate pull-up or pull-down resistors if necessary to ensure proper logic levels.
  4. Timing Considerations:

    • Account for the propagation delay (tpd) when designing the timing of your circuit.
    • Ensure setup (tsu) and hold (th) times are met to avoid data corruption.
  5. Handling:

    • Handle the device with care to avoid electrostatic discharge (ESD) damage.
    • Store and transport the device in ESD-protective packaging.
  6. Operating Temperature:

    • The device is designed to operate over a temperature range of -40°C to +85°C. Ensure the operating environment does not exceed these limits.
(For reference only)

 Inquiry - 74HC7266D