Specifications
SKU: 1559595
Parameter | Description | Min | Typ | Max | Unit |
---|---|---|---|---|---|
VCC | Supply Voltage | 2.0 | - | 6.0 | V |
ICC | Supply Current (Quiescent) | - | 1.0 | - | μA (Note 1) |
VIH | Input High Voltage | 3.15 | - | VCC | V |
VIL | Input Low Voltage | 0 | - | 0.85 | V |
VOH | Output High Voltage | 2.4 | - | VCC - 0.1 | V |
VOL | Output Low Voltage | 0 | - | 0.1 | V |
IOH | Output High Current | - | - | -4 | mA |
IOL | Output Low Current | -16 | - | - | mA |
tpd | Propagation Delay Time | 0 | 10 | 20 | ns (Note 2) |
tr | Rise Time | 0 | 5 | 10 | ns (Note 2) |
tf | Fall Time | 0 | 5 | 10 | ns (Note 2) |
tsu | Setup Time | 0 | 10 | 20 | ns (Note 2) |
th | Hold Time | 0 | 5 | 10 | ns (Note 2) |
Notes:
- Quiescent Current (ICC): The typical value is given at VCC = 4.5V and TA = 25°C.
- Timing Parameters: All timing parameters are specified at VCC = 4.5V, TA = 25°C, and with standard test conditions.
Instructions for Use:
Power Supply:
- Ensure the supply voltage (VCC) is within the range of 2.0V to 6.0V.
- Connect the ground (GND) pin to a stable reference ground.
Input Signals:
- Apply input signals that meet the VIH and VIL specifications.
- Avoid applying voltages outside the VCC range to the input pins.
Output Signals:
- Ensure the output load does not exceed the maximum output current ratings (IOH and IOL).
- Use appropriate pull-up or pull-down resistors if necessary to ensure proper logic levels.
Timing Considerations:
- Account for the propagation delay (tpd) when designing the timing of your circuit.
- Ensure setup (tsu) and hold (th) times are met to avoid data corruption.
Handling:
- Handle the device with care to avoid electrostatic discharge (ESD) damage.
- Store and transport the device in ESD-protective packaging.
Operating Temperature:
- The device is designed to operate over a temperature range of -40°C to +85°C. Ensure the operating environment does not exceed these limits.
Inquiry - 74HC7266D