Specifications
SKU: 1567210
Current Loop Receiver/Transmitter
Parameter | Symbol | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Supply Voltage | VCC | 4.5 | - | 36 | V |
Output Current | IOUT | 0 | 4 | 20 | mA |
Input Voltage Range | VIN | 0 | - | 5 | V |
Linearity Error | ELIN | - | 0.1 | - | % FSR |
Temperature Coefficient | TC | - | 50 | - | ppm/°C |
Operating Temperature | TOP | -40 | - | 85 | °C |
Storage Temperature | TSTG | -55 | - | 150 | °C |
Instructions for Using XTR115UA/2K5:
Power Supply:
- Ensure the supply voltage (VCC) is within the range of 4.5V to 36V.
- Connect the positive terminal of the power supply to VCC and the negative terminal to GND.
Input Signal:
- Apply the input voltage (VIN) to the input pin. The input voltage should be between 0V and 5V.
- Ensure the input signal is stable and within the specified range to avoid damage or incorrect operation.
Output Configuration:
- The output current (IOUT) can be set to a value between 0mA and 20mA.
- Use the appropriate load resistor to convert the current output to a voltage if needed.
Linearity and Accuracy:
- The linearity error (ELIN) is typically 0.1% of the full-scale range (FSR).
- To minimize errors, ensure the device operates within its specified temperature range and that the input signal is linear.
Temperature Considerations:
- The device is designed to operate within a temperature range of -40°C to 85°C.
- Store the device in a temperature range of -55°C to 150°C to prevent damage.
Handling and Installation:
- Handle the device with care to avoid static discharge and physical damage.
- Follow proper soldering techniques to ensure reliable connections and prevent thermal stress.
Testing and Troubleshooting:
- Verify the supply voltage and input signal before testing the output.
- If the output is not as expected, check for any open circuits or short circuits in the wiring.
- Refer to the datasheet for more detailed troubleshooting steps and application notes.