Specifications
SKU: 1569316
Circular Connector; No. of Contacts:55; Series:; Body Material:Aluminum; Connector Shell Size:22; Circular Contact Gender:Pin; Circular Shell Style:Wall Mount Receptacle; Insert Arrangement:22-55; MIL SPEC:MIL-C-26482 Series I RoHS Compliant: No
Below is the parameter table and instructions for the 2MBI300SK-060-01 IGBT module:
Parameter Table
Parameter | Symbol | Min | Typ | Max | Unit | Condition |
---|---|---|---|---|---|---|
Collector-Emitter Voltage | VCE(off) | - | - | 600 | V | IC = 0, Tj = 25°C |
Gate-Emitter Voltage | VGE(th) | 12 | 15 | 18 | V | IC = 10 A, Tj = 25°C |
Continuous Collector Current | IC(cont) | - | - | 300 | A | Tc = 25°C |
Pulse Collector Current | IC(pulse) | - | - | 600 | A | tpulse = 10 ms, Tj = 25°C |
Turn-On Time | ton | - | 0.4 | - | μs | IC = 300 A, VGE = 15 V, Rg = 4 Ω |
Turn-Off Time | toff | - | 0.6 | - | μs | IC = 300 A, VGE = -15 V, Rg = 4 Ω |
Thermal Resistance | Rth(j-c) | - | - | 0.2 | K/W | Tc = 25°C |
Junction Temperature | Tj | -55 | - | 150 | °C | - |
Storage Temperature | Tstg | -55 | - | 150 | °C | - |
Instructions
Mounting and Handling:
- Ensure that the module is handled with care to avoid mechanical damage.
- Use appropriate thermal paste or thermal interface material (TIM) between the heatsink and the module to ensure good thermal contact.
Electrical Connections:
- Connect the collector (C), emitter (E), and gate (G) terminals correctly to avoid damage.
- Use short and thick wires for low inductance connections to minimize voltage spikes during switching.
Gate Drive:
- Apply a positive gate-emitter voltage (VGE) of at least 15 V to turn on the IGBT.
- Apply a negative gate-emitter voltage (VGE) of at least -15 V to turn off the IGBT.
- Use a gate resistor (Rg) to control the turn-on and turn-off times, typically around 4 Ω.
Thermal Management:
- Ensure adequate cooling to keep the junction temperature (Tj) within the specified limits.
- Monitor the temperature of the heatsink and the module to prevent overheating.
Operating Conditions:
- Do not exceed the maximum ratings for collector-emitter voltage (VCE(off)), continuous collector current (IC(cont)), and pulse collector current (IC(pulse)).
- Avoid operating the module at temperatures outside the specified storage and junction temperature ranges.
Testing:
- Before installing the module in a circuit, test it using a suitable test setup to ensure it meets the expected performance parameters.
- Use a multimeter to check for continuity and resistance values to verify the integrity of the connections.
Storage:
- Store the module in a dry, cool place away from direct sunlight and sources of heat.
- Keep the module in its original packaging until ready for use to protect it from static discharge and physical damage.
By following these instructions, you can ensure the reliable operation and longevity of the 2MBI300SK-060-01 IGBT module.
(For reference only)Inquiry - 2MBI300SK-060-01