Specifications

SKU: 1743582

BUY CD4096BE https://www.utsource.net/itm/p/1743582.html
Logic IC
Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VDD Operating 3 18 V
Input Voltage (High) VIH VIL ≤ VIN ≤ VDD 0.7VDD VDD V
Input Voltage (Low) VIL 0 ≤ VIN ≤ VIH 0 0.3VDD V
Output Voltage (High) VOH IO = -1mA 0.9VDD VDD - 0.5 V
Output Voltage (Low) VOL IO = 1mA 0 0.1VDD + 0.5 V
Propagation Delay Time tpd VDD = 15V, fIN = 1MHz 25 35 50 ns
Power Dissipation PD Continuous 100 mW
Operating Temperature TA Commercial 0 70 °C
Storage Temperature TSTG -65 150 °C

Instructions for Using CD4096BE:

  1. Power Supply:

    • Ensure the supply voltage (VDD) is within the range of 3V to 18V.
    • Connect the ground (GND) pin to a stable reference point.
  2. Input Signals:

    • For a logic high input, ensure the input voltage (VIN) is at least 0.7 times the supply voltage (VDD).
    • For a logic low input, ensure the input voltage (VIN) is no more than 0.3 times the supply voltage (VDD).
  3. Output Signals:

    • The output voltage (VOUT) will be close to VDD for a logic high and close to 0V for a logic low.
    • Ensure the load current (IO) does not exceed the specified limits to avoid damage.
  4. Propagation Delay:

    • The propagation delay time (tpd) is the time it takes for a change in the input signal to affect the output. It varies with supply voltage and temperature.
  5. Thermal Considerations:

    • The device can operate continuously with a power dissipation up to 100mW.
    • Ensure the operating temperature (TA) is between 0°C and 70°C for commercial applications.
    • Store the device in a temperature range between -65°C and 150°C.
  6. Handling:

    • Handle the device with care to avoid static discharge, which can damage the internal circuits.
    • Use appropriate ESD protection measures when handling or soldering the device.
  7. Testing:

    • Test the device under typical operating conditions to ensure it meets the specified parameters.
    • Use a multimeter to verify the supply voltage and output levels.

By following these instructions, you can ensure reliable operation of the CD4096BE.