Specifications
SKU: 1836944
Smart Two Channel Highside Power Switch
Below is the parameter table and instructions for the BTS612N1E3128A, a high-side switch from Infineon Technologies.
BTS612N1E3128A Parameter Table
Parameter | Symbol | Min | Typ | Max | Unit | Condition |
---|---|---|---|---|---|---|
Supply Voltage | VCC | 4.5 | - | 40 | V | - |
Continuous Load Current | IOUT | - | 8 | 16 | A | TC = 25°C |
Peak Load Current | IOUT,PK | - | 25 | 35 | A | tPK = 10 ms, TC = 25°C |
On-State Resistance | RDS(on) | - | 18 | 24 | mΩ | VGS = 10V, IOUT = 8A |
Thermal Shutdown Temperature | TSD | - | 170 | - | °C | - |
Operating Junction Temperature | TJ(op) | -25 | - | 150 | °C | - |
Storage Temperature Range | TSTG | -40 | - | 150 | °C | - |
Maximum Power Dissipation | PD | - | - | 250 | W | TC = 25°C |
Gate-Source Voltage | VGS | -20 | - | 20 | V | - |
Gate-Source Threshold Voltage | VGS(th) | 1.5 | 2.5 | 4.0 | V | ID = 1mA |
Leakage Current at Output | ILEAK | - | 1 | 10 | μA | VOUT = 40V, TA = 25°C |
Input Capacitance | Ciss | - | 100 | 150 | pF | VGS = 0V, f = 1MHz |
Instructions for BTS612N1E3128A
Supply Voltage (VCC):
- Ensure the supply voltage is within the range of 4.5V to 40V.
- Do not exceed the maximum supply voltage to avoid damaging the device.
Load Current (IOUT):
- The continuous load current should not exceed 16A at a case temperature of 25°C.
- For peak currents, ensure that the duration does not exceed 10ms to avoid thermal stress.
Thermal Management:
- Monitor the junction temperature to ensure it does not exceed 150°C.
- Use appropriate heat sinks or cooling methods to manage power dissipation, especially when operating at high currents.
Gate Drive:
- Apply a gate-source voltage (VGS) within the range of -20V to +20V.
- The threshold voltage (VGS(th)) is typically between 1.5V and 4.0V for a drain current of 1mA.
Leakage Current:
- The leakage current at the output should be monitored and kept below 10μA to ensure proper operation.
Storage and Handling:
- Store the device in a dry environment with temperatures between -40°C and 150°C.
- Handle the device with care to avoid static discharge, which can damage the internal components.
Protection Features:
- The device includes thermal shutdown protection, which will activate if the junction temperature exceeds 170°C.
- Ensure that the device is properly mounted and connected to prevent any potential overcurrent or overvoltage conditions.
By following these parameters and instructions, you can ensure the reliable and safe operation of the BTS612N1E3128A high-side switch.
(For reference only)Inquiry - BTS612N1E3128A