Specifications
SKU: 1885983
Parameter | Symbol | Min | Typical | Max | Unit | Notes |
---|---|---|---|---|---|---|
Input Voltage | VIN | 2.7 | - | 5.5 | V | Operating range |
Output Voltage | VOUT | - | 3.3 | - | V | Fixed output |
Output Current | IOUT | - | 300 | - | mA | Continuous |
Quiescent Current | IQ | - | 1.5 | - | μA | Shutdown mode |
Dropout Voltage | VDO | - | 0.3 | - | V | At IOUT = 300mA |
Load Regulation | - | - | 0.5 | - | % | 10mA to 300mA |
Line Regulation | - | - | 0.01 | - | %/V | Over full input range |
Ripple Rejection | - | - | 60 | - | dB | @ 1kHz |
Operating Temperature | TOP | -40 | - | 85 | °C | Storage and operation |
Storage Temperature | TSTG | -40 | - | 125 | °C | - |
Thermal Resistance | θJA | - | 60 | - | °C/W | - |
Instructions for Use
Power Supply Connection:
- Connect the input voltage (VIN) to the VIN pin.
- Ensure the input voltage is within the operating range (2.7V to 5.5V).
Output Connection:
- Connect the load to the VOUT pin.
- The output voltage is fixed at 3.3V.
Ground Connection:
- Connect the ground (GND) pin to the common ground of the circuit.
Capacitors:
- Place a 1μF ceramic capacitor between VIN and GND as close to the device as possible.
- Place a 1μF ceramic capacitor between VOUT and GND as close to the device as possible.
Thermal Management:
- Ensure adequate heat dissipation, especially when operating at high output currents.
- The thermal resistance (θJA) is 60°C/W, so consider using a heatsink if necessary.
Shutdown Mode:
- To enter shutdown mode, pull the EN (Enable) pin low.
- The quiescent current in shutdown mode is typically 1.5μA.
Operating Temperature:
- The device is rated to operate from -40°C to 85°C.
- Store the device between -40°C and 125°C.
Ripple Rejection:
- The device provides 60dB ripple rejection at 1kHz, which helps in maintaining a stable output voltage under varying input conditions.
Load and Line Regulation:
- The load regulation is 0.5%, ensuring minimal output voltage change with varying load currents.
- The line regulation is 0.01%/V, ensuring minimal output voltage change with varying input voltages.
Handling Precautions:
- Handle the device with care to avoid static damage.
- Follow standard ESD (Electrostatic Discharge) precautions when handling the device.
Inquiry - STR-Z4302A