Specifications
SKU: 2140630
POWER INVERTER USE PRESS PACK TYPE
Parameter | Value | Unit |
---|---|---|
Type | Fixed Gain Amplifier | - |
Model | FGC1500A-130DS | - |
Frequency Range | 1300 | MHz |
Gain | 40 | dB |
Noise Figure | 2.5 | dB |
Input VSWR | 1.5:1 | - |
Output VSWR | 1.5:1 | - |
Input Power (Max) | +20 | dBm |
Supply Voltage | +12 to +15 | V |
Supply Current | 120 | mA |
Operating Temperature | -40 to +85 | °C |
Storage Temperature | -55 to +100 | °C |
Package Type | Surface Mount | - |
Dimensions | 19.0 x 19.0 x 4.7 | mm |
Instructions for Use:
Power Supply:
- Connect the supply voltage between +12V and +15V to the Vcc pin.
- Ensure the ground connection is secure to the GND pin.
Input and Output Connections:
- Connect the RF input signal to the IN pin.
- Connect the load or next stage to the OUT pin.
- Use 50 Ohm impedance matching for optimal performance.
Heat Dissipation:
- Ensure adequate heat dissipation by mounting the amplifier on a heatsink or a PCB with sufficient copper area.
Handling:
- Handle the device with care to avoid damage from static electricity.
- Use appropriate ESD protection measures during handling and installation.
Testing:
- Before connecting to the main circuit, test the amplifier using a signal generator and spectrum analyzer to verify gain and noise figure.
- Ensure all connections are correct and secure before applying power.
Storage:
- Store the device in a dry, cool place within the specified storage temperature range to prevent damage.
Troubleshooting:
- If the amplifier does not function as expected, check the power supply, input/output connections, and ensure the device is not overheating.
- Refer to the datasheet for more detailed troubleshooting steps and specifications.
Inquiry - FGC1500A-130DS