Specifications
SKU: 4005305
Parameter | Symbol | Min | Typ | Max | Unit | Notes |
---|---|---|---|---|---|---|
Breakdown Voltage | V(BR) | - | 500 | - | V | Reverse direction |
Maximum Drain Current | ID | - | 8 | - | A | Continuous, Tc = 25°C |
Peak Pulse Current | Ipp | - | 16 | - | A | t = 10 ms, duty cycle = 1% |
On-State Voltage | V(on) | - | 1.2 | - | V | At ID = 8A |
Gate Threshold Voltage | Vth | 2 | 4 | 6 | V | Gate to source |
Total Power Dissipation | PD | - | 75 | - | W | Tc = 25°C |
Junction Temperature | Tj | -55 | - | 150 | °C | Operating range |
Storage Temperature | Tstg | -55 | - | 150 | °C | Storage and non-operating range |
Instructions for Use:
Mounting and Handling:
- Ensure proper heat sinking to maintain the junction temperature within the specified range.
- Handle the device with care to avoid damage to the leads and the body.
Electrical Connections:
- Connect the drain (D) to the high voltage side of the circuit.
- Connect the source (S) to the low voltage side or ground.
- Apply the gate (G) signal to control the switching of the device.
Operating Conditions:
- Do not exceed the maximum ratings for breakdown voltage, drain current, and power dissipation.
- Ensure that the gate threshold voltage is met to properly turn on the device.
Thermal Management:
- Use appropriate thermal management techniques to keep the junction temperature below the maximum rating.
- Consider using a heatsink or forced air cooling for continuous operation at high currents.
Pulse Operation:
- For pulse applications, ensure that the peak pulse current does not exceed the specified limit and that the duty cycle is within the allowed range.
Storage:
- Store the device in a dry, cool environment within the specified storage temperature range.
Safety Precautions:
- Always follow safe handling practices to avoid electrical shock.
- Use appropriate protective equipment when working with high voltages and currents.
Testing:
- Test the device under controlled conditions to ensure it meets the required specifications before integrating it into the final application.
Inquiry - 08N50E