Share:


ADG409BNZ

Specifications

SKU: 4180445

BUY ADG409BNZ https://www.utsource.net/itm/p/4180445.html
MULTIPLEXER DUAL 4X1 16DIP
Parameter Description Min Typ Max Unit
Supply Voltage (VDD) Operating supply voltage range 2.7 - 36 V
Supply Current (IDD) Quiescent supply current per channel - 1.5 - μA
Channel Resistance (RON) On-state resistance - 150 - Ω
Leakage Current (ILEAK) Leakage current at VDD/2 - 1 - nA
Breakdown Voltage (VBR) Maximum voltage across any pin - - 36 V
Switching Time (tsw) Time to switch from off to on or on to off - 1 - μs
Input Signal Range Input signal range relative to ground -VDD + 1.5 - VDD - 1.5 V
Operating Temperature (TA) Ambient operating temperature range -40 - 85 °C
Storage Temperature (TSTG) Storage temperature range -65 - 150 °C

Instructions for Using ADG409BNZ

  1. Power Supply:

    • Ensure the supply voltage (VDD) is within the specified range of 2.7V to 36V.
    • Connect the power supply to the VDD and GND pins.
  2. Signal Input:

    • The input signals should be within the range of -VDD + 1.5V to VDD - 1.5V to avoid damaging the device.
    • Connect the input signals to the appropriate channels.
  3. Control Signals:

    • Use the control inputs (INx) to select which channel is active.
    • Apply logic high (VDD) or low (GND) to the control inputs to switch the corresponding channel on or off.
  4. Output Handling:

    • The output signals will follow the selected input channel when the switch is on.
    • Ensure the load connected to the output can handle the current and voltage levels.
  5. Thermal Management:

    • Operate the device within the ambient temperature range of -40°C to 85°C.
    • If operating in high-temperature environments, ensure adequate cooling to prevent overheating.
  6. Storage:

    • Store the device in a dry environment within the temperature range of -65°C to 150°C.
  7. Handling:

    • Handle the device with care to avoid static discharge, which can damage the internal components.
    • Use proper ESD protection measures during handling and installation.
  8. Testing:

    • Before connecting to your application, test the device using a known good setup to verify its functionality.
    • Measure the on-state resistance (RON) and leakage current (ILEAK) to ensure they are within the specified limits.

By following these instructions, you can ensure reliable operation and longevity of the ADG409BNZ analog switch.

(For reference only)

 Inquiry - ADG409BNZ