Specifications
SKU: 4478170
Parameter | Value/Description |
---|---|
Part Number | G4W-2212P-US-TV5-12VDC |
Type | Reed Relay |
Coil Voltage | 12VDC |
Coil Power | 0.36W |
Coil Resistance | 400Ω |
Operating Current | 30mA |
Pickup Voltage | 8.4VDC (min) |
Dropout Voltage | 1.2VDC (max) |
Contact Form | SPDT (Single Pole Double Throw) |
Contact Rating | 5A @ 250VAC, 3A @ 125VDC |
Contact Resistance | 50mΩ (max) |
**Insulation Resistance | 100MΩ (min) @ 500VDC |
Dielectric Strength | 1500VAC (rms) for 1 minute |
Mechanical Life | 100 million operations (min) |
Electrical Life | 100,000 operations (min) at rated load |
**Operating Temperature | -40°C to +85°C |
Storage Temperature | -40°C to +125°C |
Humidity | 95% RH (non-condensing) |
Dimensions | 22.1mm x 12.1mm x 12.1mm |
Weight | 4.5g |
Mounting | Surface Mount (SMD) |
Approvals | UL, CSA, CE |
Instructions:
Handling and Storage:
- Store the relay in a dry, clean environment with temperatures between -40°C and +125°C.
- Avoid exposure to high humidity and condensation.
Installation:
- Ensure proper handling to avoid damage to the relay.
- Use appropriate soldering techniques and temperatures to avoid thermal shock.
- Follow the recommended PCB layout and spacing guidelines.
Operation:
- Apply the specified coil voltage (12VDC) to activate the relay.
- Ensure the operating current does not exceed 30mA.
- Do not exceed the maximum pickup and dropout voltages.
- Verify that the contact load does not exceed the rated values (5A @ 250VAC, 3A @ 125VDC).
Testing:
- Test the relay under the specified operating conditions to ensure reliable performance.
- Check the contact resistance and insulation resistance regularly.
Maintenance:
- Inspect the relay periodically for signs of wear or damage.
- Replace the relay if it fails to meet the specified performance parameters.
Safety:
- Ensure proper grounding and isolation to prevent electrical hazards.
- Follow all safety guidelines and regulations when using the relay in your application.
Inquiry - G4W-2212P-US-TV5-12VDC