Specifications
SKU: 4502249
Parameter | Description | Value |
---|---|---|
Device Type | Non-Volatile Static RAM (NVS RAM) | - |
Organization | 8K x 8 bits | - |
Supply Voltage (VCC) | Operating Range | 4.5V to 5.5V |
Standby Current (ISB) | VCC = 5V, VPP = 0V, CS = VCC, WE = VCC | 1 μA max |
Active Current (IACT) | VCC = 5V, VPP = 0V, All Inputs Active | 30 mA max |
Access Time (tAC) | VCC = 5V, VPP = 0V, tC = 0 ns | 120 ns typ |
Write Cycle Time (tWC) | VCC = 5V, VPP = 0V | 150 ns min |
Data Hold Time (tDH) | VCC = 5V, VPP = 0V | 0 ns min |
Data Setup Time (tDS) | VCC = 5V, VPP = 0V | 20 ns min |
Address Access Time (tAA) | VCC = 5V, VPP = 0V | 25 ns max |
Output Enable Time (tOE) | VCC = 5V, VPP = 0V | 20 ns min |
Output Disable Time (tOH) | VCC = 5V, VPP = 0V | 20 ns min |
Chip Select Time (tCS) | VCC = 5V, VPP = 0V | 20 ns min |
Write Enable Time (tWE) | VCC = 5V, VPP = 0V | 20 ns min |
Package | DIP-28, PLCC-28, SOP-28 | - |
Operating Temperature Range | Industrial Grade | -40°C to +85°C |
Instructions for Use
Power Supply:
- Connect VCC to the positive power supply (4.5V to 5.5V).
- Connect VSS to ground (0V).
Signal Connections:
- Address Lines (A0-A12): Connect these to the address bus of your system.
- Data Lines (D0-D7): Connect these to the data bus of your system.
- Chip Select (CS): Active low. When CS is low, the device is selected.
- Write Enable (WE): Active low. When WE is low, a write operation is performed.
- Output Enable (OE): Active low. When OE is low, the outputs are enabled.
Read Operation:
- Set the address lines to the desired memory location.
- Set CS and OE low to enable the device and the outputs.
- The data at the specified address will appear on the data lines after the access time (tAC).
Write Operation:
- Set the address lines to the desired memory location.
- Set the data lines to the data you want to write.
- Set CS and WE low to initiate the write operation.
- Maintain WE low for at least the write cycle time (tWC).
Standby Mode:
- Set CS high to put the device in standby mode, which reduces power consumption.
Temperature Considerations:
- Ensure that the operating temperature is within the specified range (-40°C to +85°C) to avoid damage or unreliable operation.
Handling:
- Handle the device with care to avoid static discharge, which can damage the chip.
- Follow standard ESD (Electrostatic Discharge) precautions when handling and installing the device.
Inquiry - HM6264-12