Specifications
SKU: 4569071
MOSFET N-CH 150V 104A TO220AB
Parameter | Symbol | Min | Typical | Max | Unit | Conditions |
---|---|---|---|---|---|---|
Continuous Drain Current | ID | - | 140 | - | A | TC = 25°C, VGS = 10V |
Pulse Drain Current | IDpeak | - | 630 | - | A | TC = 25°C, t = 10μs, Duty Cycle = 1% |
Gate-Source Voltage | VGS | -15 | - | 15 | V | - |
Drain-Source Breakdown Voltage | V(BR)DSS | 55 | - | 60 | V | - |
Gate-Source Leakage Current | IGSS | -1 | - | 1 | μA | VGS = ±15V, TC = 25°C |
Drain-Source On-State Resistance | RDS(on) | 3.5 | - | 4.5 | mΩ | VGS = 10V, ID = 140A, TC = 25°C |
Gate Charge | QG | - | 98 | - | nC | VGS = 10V, VDS = 25V, ID = 140A |
Input Capacitance | Ciss | - | 2600 | - | pF | VGS = 0V, f = 1MHz |
Output Capacitance | Coss | - | 770 | - | pF | VDS = 25V, f = 1MHz |
Reverse Transfer Capacitance | Crss | - | 600 | - | pF | VDS = 25V, VGS = 0V, f = 1MHz |
Total Power Dissipation | PD | - | - | 150 | W | TC = 25°C |
Junction Temperature | TJ | -55 | - | 150 | °C | - |
Storage Temperature Range | TSTG | -55 | - | 150 | °C | - |
Instructions for Use:
Handling and Storage:
- Store in a dry, cool place to prevent moisture damage.
- Handle with care to avoid mechanical stress or damage to the leads.
Mounting:
- Ensure proper heat sinking to manage thermal dissipation, especially when operating at high currents.
- Use thermal paste between the device and heat sink for better thermal conductivity.
Electrical Connections:
- Ensure that all connections are secure and free from corrosion.
- Use appropriate wire gauges to handle the current levels.
Gate Drive:
- Use a gate driver circuit to provide sufficient drive current for fast switching.
- Ensure the gate voltage (VGS) is within the specified range to avoid damage.
Overcurrent Protection:
- Implement overcurrent protection to prevent damage from excessive current.
- Monitor the drain current (ID) and limit it to the maximum continuous rating.
Thermal Management:
- Regularly check the temperature of the device to ensure it does not exceed the maximum junction temperature (TJ).
- Use forced air cooling if necessary to maintain safe operating temperatures.
Testing:
- Test the device under controlled conditions to verify its performance before integrating it into the final application.
- Use appropriate test equipment and procedures to avoid damaging the device.
Compliance:
- Ensure that the device is used in compliance with relevant safety and regulatory standards.
Inquiry - IRFB4115PBF