Parameter Symbol Min Typical Max Unit Conditions
Continuous Drain Current ID - 140 - A TC = 25°C, VGS = 10V
Pulse Drain Current IDpeak - 630 - A TC = 25°C, t = 10μs, Duty Cycle = 1%
Gate-Source Voltage VGS -15 - 15 V -
Drain-Source Breakdown Voltage V(BR)DSS 55 - 60 V -
Gate-Source Leakage Current IGSS -1 - 1 μA VGS = ±15V, TC = 25°C
Drain-Source On-State Resistance RDS(on) 3.5 - 4.5 VGS = 10V, ID = 140A, TC = 25°C
Gate Charge QG - 98 - nC VGS = 10V, VDS = 25V, ID = 140A
Input Capacitance Ciss - 2600 - pF VGS = 0V, f = 1MHz
Output Capacitance Coss - 770 - pF VDS = 25V, f = 1MHz
Reverse Transfer Capacitance Crss - 600 - pF VDS = 25V, VGS = 0V, f = 1MHz
Total Power Dissipation PD - - 150 W TC = 25°C
Junction Temperature TJ -55 - 150 °C -
Storage Temperature Range TSTG -55 - 150 °C -

Instructions for Use:

  1. Handling and Storage:

    • Store in a dry, cool place to prevent moisture damage.
    • Handle with care to avoid mechanical stress or damage to the leads.
  2. Mounting:

    • Ensure proper heat sinking to manage thermal dissipation, especially when operating at high currents.
    • Use thermal paste between the device and heat sink for better thermal conductivity.
  3. Electrical Connections:

    • Ensure that all connections are secure and free from corrosion.
    • Use appropriate wire gauges to handle the current levels.
  4. Gate Drive:

    • Use a gate driver circuit to provide sufficient drive current for fast switching.
    • Ensure the gate voltage (VGS) is within the specified range to avoid damage.
  5. Overcurrent Protection:

    • Implement overcurrent protection to prevent damage from excessive current.
    • Monitor the drain current (ID) and limit it to the maximum continuous rating.
  6. Thermal Management:

    • Regularly check the temperature of the device to ensure it does not exceed the maximum junction temperature (TJ).
    • Use forced air cooling if necessary to maintain safe operating temperatures.
  7. Testing:

    • Test the device under controlled conditions to verify its performance before integrating it into the final application.
    • Use appropriate test equipment and procedures to avoid damaging the device.
  8. Compliance:

    • Ensure that the device is used in compliance with relevant safety and regulatory standards.