Specifications
SKU: 4914516
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Supply Voltage | Vcc | Operating | 2.7 | - | 3.6 | V |
Standby Current | Icc | Vcc = 3.0V | - | 1.0 | - | μA |
Active Current | Icc | Read @ 10 MHz | - | 2.0 | - | mA |
Programming Current | Icc | Write @ 10 MHz | - | 6.0 | - | mA |
Data Retention Time | Tr | 10 | - | - | years | |
Operating Temperature Range | Topr | Commercial | -40 | - | 85 | °C |
Industrial Temperature Range | Topr | Industrial | -40 | - | 105 | °C |
Storage Temperature Range | Tstg | -65 | - | 150 | °C | |
Write Cycle Time | tWC | 5 | - | - | ms | |
Page Program Time | tPP | 2.5 | - | - | ms | |
Sector Erase Time | tSE | 200 | - | - | ms | |
Block Erase Time | tBE | 300 | - | - | ms | |
Chip Erase Time | tCE | 3000 | - | - | ms | |
Data Output High Level | VOH | Vcc = 3.0V | 2.4 | - | - | V |
Data Output Low Level | VOL | Vcc = 3.0V | - | - | 0.4 | V |
Input High Voltage | VIH | 2.0 | - | - | V | |
Input Low Voltage | VIL | - | - | 0.8 | V |
Instructions for Use:
Power Supply:
- Ensure the supply voltage (Vcc) is within the range of 2.7V to 3.6V.
- The device should be powered down properly to avoid data corruption.
Current Consumption:
- Monitor the standby current (Icc) which should not exceed 1.0 μA at 3.0V.
- During active operations (read/write), the current consumption can reach up to 6.0 mA.
Temperature Ranges:
- For commercial applications, operate the device between -40°C and 85°C.
- For industrial applications, the operating temperature range is -40°C to 105°C.
- Store the device between -65°C and 150°C.
Timing Parameters:
- Respect the write cycle time (tWC) of 5 ms to ensure reliable data programming.
- Page program time (tPP) is 2.5 ms.
- Sector erase time (tSE) is 200 ms.
- Block erase time (tBE) is 300 ms.
- Chip erase time (tCE) is 3000 ms.
Signal Levels:
- Ensure that the data output high level (VOH) is at least 2.4V when Vcc is 3.0V.
- The data output low level (VOL) should not exceed 0.4V.
- Input signals should have a high voltage (VIH) of at least 2.0V and a low voltage (VIL) not exceeding 0.8V.
Programming and Erasing:
- Follow the specific command sequences for programming and erasing as detailed in the device datasheet.
- Verify the status register after each operation to ensure successful completion.
Data Retention:
- The device is designed to retain data for at least 10 years under normal operating conditions.
Handling and Storage:
- Handle the device with care to avoid static discharge, which can damage the component.
- Store the device in a dry, cool environment to prevent moisture-related issues.
For more detailed information, refer to the full datasheet provided by the manufacturer.
(For reference only)Inquiry - MX25L8006EM1I-12G