Specifications
SKU: 5255544
Parameter | Symbol | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Supply Voltage | Vcc | 18 | - | 30 | V |
Quiescent Current | Iq | - | 40 | - | mA |
Output Power (8Ω) | Po(8Ω) | - | 2x25 | - | W |
Total Harmonic Distortion (THD) | THD | - | 0.1 | - | % |
Signal-to-Noise Ratio | SNR | - | 85 | - | dB |
Input Sensitivity | Vi | - | 250 | - | mV |
Input Impedance | Zi | - | 47 | - | kΩ |
Operating Temperature | Temp | -25 | - | 85 | °C |
Instructions for TDA1519CL
Supply Voltage:
- Ensure the supply voltage is within the range of 18V to 30V. Operating outside this range can damage the device.
Quiescent Current:
- The quiescent current is typically around 40mA. This value should be considered when designing the power supply.
Output Power:
- The TDA1519CL can deliver up to 2x25W into an 8Ω load. Ensure the speakers and load impedance match this specification to avoid damage.
Total Harmonic Distortion (THD):
- The typical THD is 0.1%. This low distortion ensures high audio quality.
Signal-to-Noise Ratio (SNR):
- The SNR is typically 85dB, providing a clean and clear audio signal.
Input Sensitivity:
- The input sensitivity is 250mV. Adjust the input signal level to match this value for optimal performance.
Input Impedance:
- The input impedance is 47kΩ. This high impedance minimizes loading effects on the signal source.
Operating Temperature:
- The operating temperature range is from -25°C to 85°C. Ensure the device is used within this range to prevent thermal damage.
Mounting and Layout:
- Use proper heat sinking to manage thermal dissipation. Ensure good ventilation and avoid placing the device near heat sources.
Protection Circuits:
- The TDA1519CL includes built-in protection circuits for short-circuit, over-temperature, and over-voltage conditions. However, it is still important to design the circuit with these protections in mind.
Power-Up and Power-Down:
- Ensure a smooth power-up and power-down sequence to avoid pops or clicks in the audio output. Use a soft-start circuit if necessary.
Grounding:
- Proper grounding is crucial for reducing noise and ensuring stable operation. Use a star grounding technique to minimize ground loops.
Inquiry - TDA1519CL