Specifications

SKU: 6335804

BUY NE5534ADR2 https://www.utsource.net/itm/p/6335804.html
Single Low Noise Operational Amplifier
Parameter Symbol Min Typical Max Unit Notes
Supply Voltage Vcc ±10 ±18 V
Supply Current (per op-amp) Icc 2.5 mA
Input Offset Voltage Vio -0.5 0.5 mV
Input Bias Current Ib -0.5 0.5 nA
Input Offset Current Ios -0.05 0.05 nA
Input Voltage Range Vin -13 13 V
Output Voltage Swing Vout -13 13 V
Slew Rate SR 13 V/μs
Gain Bandwidth Product GBP 10 MHz
Large Signal Voltage Gain Av 100 1000 dB
Common Mode Rejection Ratio CMRR 90 100 dB
Power Supply Rejection Ratio PSRR 90 100 dB
Operating Temperature Temp -40 85 °C

Instructions for Using the NE5534ADR2

  1. Power Supply:

    • The NE5534ADR2 operates with a dual supply voltage ranging from ±10V to ±18V. Ensure that the power supply is stable and within these limits to avoid damage to the device.
  2. Input Signals:

    • The input voltage range is from -13V to +13V. Ensure that input signals do not exceed these limits to prevent distortion or damage.
    • Use appropriate input coupling capacitors if necessary to block any DC offset.
  3. Output Signals:

    • The output voltage swing can reach from -13V to +13V. Ensure that the load impedance is compatible with the output current capability of the op-amp.
    • Use output coupling capacitors if necessary to block any DC offset.
  4. Biasing:

    • The input bias current is very low, typically around 0.5 nA. Use high-value resistors for biasing to minimize loading effects on the input signal.
  5. Offset Adjustment:

    • If precise offset adjustment is required, use external resistors and a potentiometer to nullify the input offset voltage.
  6. Stability:

    • The NE5534ADR2 has a gain bandwidth product of 10 MHz. Ensure that the circuit design does not exceed this bandwidth to maintain stability.
    • Use appropriate compensation techniques if operating at high frequencies.
  7. Temperature Considerations:

    • The operating temperature range is from -40°C to 85°C. Ensure that the device is used within this range to avoid performance degradation or failure.
  8. Mounting and Handling:

    • Handle the device with care to avoid static discharge, which can damage the sensitive components.
    • Follow proper soldering techniques and ensure that the device is securely mounted on the PCB.

By following these guidelines, you can ensure optimal performance and reliability of the NE5534ADR2 in your application.