Cold-Junction Compensated Thermocouple-to-Digital Converter
Parameter Description Min Typ Max Unit
VCC Supply Voltage 2.7 3.3 5.5 V
ICC Supply Current (typical) - 1.0 - mA
VIN+ Input Voltage Range (Thermocouple) -2.0 - +18.0 V
VREF Reference Voltage 2.4 2.5 2.6 V
Tcj Junction Temperature Range -40 - 125 °C
Tcold Cold-Junction Temperature Range -40 - 125 °C
Tcj Acc Cold-Junction Temperature Accuracy - ±2.0 - °C
Tcj Res Cold-Junction Temperature Resolution - 0.0625 - °C
Ttherm Thermocouple Temperature Range -200 - 700 °C (K-Type)
Ttherm Acc Thermocouple Temperature Accuracy - ±2.0 - °C
Ttherm Res Thermocouple Temperature Resolution - 0.25 - °C
Conversion Time Time to Convert a Reading - 9.8 - ms
SPI Clock Maximum SPI Clock Frequency - 5 - MHz
Output Data Rate Data Output Rate - 1 - Hz

Instructions for Using the MAX31855KASA

  1. Power Supply:

    • Connect the VCC pin to a supply voltage between 2.7V and 5.5V.
    • Ensure the supply current does not exceed 1.0mA.
  2. Thermocouple Connection:

    • Connect the thermocouple leads to the VIN+ and VIN- pins.
    • The input voltage range for the thermocouple is from -2.0V to +18.0V.
  3. Cold-Junction Compensation:

    • The cold-junction temperature is automatically measured by the device.
    • The accuracy of the cold-junction temperature is ±2.0°C with a resolution of 0.0625°C.
  4. Thermocouple Temperature Measurement:

    • The device measures the thermocouple temperature over a range of -200°C to 700°C for K-type thermocouples.
    • The accuracy of the thermocouple temperature is ±2.0°C with a resolution of 0.25°C.
  5. SPI Communication:

    • Use the SPI interface to read the temperature data.
    • The maximum SPI clock frequency is 5MHz.
    • The conversion time for a single reading is 9.8ms.
  6. Data Output:

    • The data output rate is 1Hz.
    • Read the 14-bit temperature data from the SPI interface.
  7. Operating Temperature:

    • The device operates over a junction temperature range of -40°C to 125°C.
  8. Handling and Storage:

    • Store the device in a dry environment to prevent moisture damage.
    • Handle with care to avoid mechanical stress on the pins and package.

By following these instructions, you can ensure reliable and accurate temperature measurements using the MAX31855KASA.

(For reference only)