Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Supply Voltage | VCC | - | 2.7 | 3.3 | 5.5 | V |
Power Consumption | ICC | VCC = 3.3V, BCK = 2.822MHz, active mode | - | 20 | - | mA |
Power Consumption (Standby) | ICCS | VCC = 3.3V, standby mode | - | 0.5 | - | μA |
Differential Input Voltage | VIN | - | - | 2.0 | - | Vpp |
Signal-to-Noise Ratio | SNR | A-weighted, 20Hz to 20kHz, THD+N < 0.01% | - | 120 | - | dB |
Total Harmonic Distortion + Noise | THD+N | 20Hz to 20kHz, 0dBFS, 1kHz | - | 0.0009 | - | % |
Dynamic Range | DR | A-weighted, 20Hz to 20kHz | - | 120 | - | dB |
Channel Separation | CS | 20Hz to 20kHz, 0dBFS | - | 110 | - | dB |
Clock Frequency | BCK | - | 2.822 | - | 11.288 | MHz |
Data Format | - | - | I2S, | - | DSD | - |
Operating Temperature | TOPR | - | -40 | - | 85 | °C |
Storage Temperature | TSTG | - | -40 | - | 85 | °C |
Instructions for Use
Power Supply:
- Ensure the supply voltage (VCC) is within the range of 2.7V to 5.5V.
- Connect a decoupling capacitor (typically 10μF) between VCC and GND to stabilize the power supply.
Clock Configuration:
- The bit clock (BCK) should be set between 2.822MHz and 11.288MHz.
- The master clock (MCLK) should be an integer multiple of the bit clock.
Data Format:
- The AK4413EQ supports I2S, Left-Justified, Right-Justified, and DSD data formats.
- Configure the data format using the control register settings.
Signal Input:
- The differential input voltage should not exceed 2.0Vpp.
- Ensure the input signals are properly balanced and within the specified range.
Power Management:
- To enter standby mode, set the appropriate bit in the control register.
- In standby mode, the power consumption drops to approximately 0.5μA.
Temperature Considerations:
- Operate the device within the temperature range of -40°C to 85°C.
- Store the device within the same temperature range to avoid damage.
Signal-to-Noise Ratio (SNR):
- The SNR is measured with A-weighting over the frequency range of 20Hz to 20kHz.
- Ensure the system design minimizes external noise sources to achieve the best performance.
Total Harmonic Distortion + Noise (THD+N):
- The THD+N is measured at 1kHz with a 0dBFS signal level.
- Keep the signal path clean and avoid overdriving the inputs to maintain low distortion.
Channel Separation:
- The channel separation is measured over the frequency range of 20Hz to 20kHz.
- Proper layout and shielding can help improve channel separation.
Dynamic Range:
- The dynamic range is also measured with A-weighting over the frequency range of 20Hz to 20kHz.
- Optimize the analog front-end and back-end stages to maximize the dynamic range.
For detailed configuration and programming, refer to the datasheet and application notes provided by Asahi Kasei Microdevices (AKM).