Specifications
SKU: 8647722
Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
---|---|---|---|---|---|---|
Drain-Source Voltage | VDS | -55 | - | -100 | V | - |
Gate-Source Voltage | VGS | -20 | - | 20 | V | - |
Continuous Drain Current | ID | - | 36 | 59 | A | TC = 25°C |
Pulse Drain Current | ID(p) | - | 88 | 120 | A | tp = 10 μs, TC = 25°C |
Power Dissipation | PD | - | - | 175 | W | TC = 25°C |
Junction Temperature | TJ | - | - | 175 | °C | - |
Storage Temperature | TSTG | -55 | - | 150 | °C | - |
Total Gate Charge | QG | - | 110 | 140 | nC | VGS = 10V, ID = 36A |
Input Capacitance | Ciss | - | 1500 | 2000 | pF | VDS = 100V |
Output Capacitance | Coss | - | 360 | 480 | pF | VDS = 100V |
Reverse Transfer Capacitance | Crss | - | 240 | 320 | pF | VDS = 100V |
Drain-Source On-Resistance | RDS(on) | - | 4.4 | 5.5 | mΩ | VGS = 10V, ID = 36A |
Instructions for Use:
Handling Precautions:
- The IRF1404ZLPBF is sensitive to electrostatic discharge (ESD). Use proper ESD protection when handling.
- Avoid exceeding the maximum ratings listed in the table to prevent damage to the device.
Mounting:
- Ensure good thermal management by using a heatsink or heat spreader to dissipate the power generated during operation.
- Follow recommended PCB layout guidelines to minimize parasitic inductances and improve performance.
Biasing:
- Apply the gate-source voltage (VGS) carefully to avoid exceeding the maximum ratings.
- Use a gate resistor to limit the current and reduce ringing on the gate signal.
Operation:
- Ensure the junction temperature (TJ) does not exceed 175°C to maintain reliable operation.
- For pulse applications, ensure the pulse width and frequency are within the safe operating area (SOA).
Testing:
- When testing the device, use appropriate test equipment and methods to accurately measure parameters such as RDS(on) and QG.
- Refer to the datasheet for specific test conditions and procedures.
Storage:
- Store the device in a dry, cool place away from direct sunlight and sources of heat.
- Keep the device in its original packaging until ready for use to protect against ESD and physical damage.
By following these instructions, you can ensure the optimal performance and longevity of the IRF1404ZLPBF.
(For reference only)Inquiry - IRF1404ZLPBF