Specifications
SKU: 8656867
Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
---|---|---|---|---|---|---|
Breakdown Voltage | V(BR)DSS | - | 650 | - | V | Drain-Source, Gate Open |
Drain-Source On-State Resistance | RDS(on) | - | 0.28 | - | Ω | VGS = 10V, ID = 30A |
Continuous Drain Current | ID | - | 30 | - | A | Tc = 25°C, VGS = 10V |
Pulse Drain Current | Ipp | - | 120 | - | A | tP = 10μs, Duty Cycle ≤ 1% |
Gate Threshold Voltage | VGS(th) | 2.0 | 4.0 | 6.0 | V | ID = 250μA, Tj = 25°C |
Input Capacitance | Ciss | - | 1700 | - | pF | VDS = 0V, f = 1MHz |
Output Capacitance | Coss | - | 220 | - | pF | VDS = 650V, f = 1MHz |
Reverse Transfer Capacitance | Crss | - | 350 | - | pF | VDS = 650V, f = 1MHz |
Total Gate Charge | Qg | - | 95 | - | nC | VGS = 15V, VDS = 650V, ID = 30A |
Gate-to-Source Charge | Qgs | - | 32 | - | nC | VGS = 15V, VDS = 650V, ID = 30A |
Gate-to-Drain Charge | Qgd | - | 63 | - | nC | VGS = 15V, VDS = 650V, ID = 30A |
Junction Temperature | Tj | - | - | 175 | °C | - |
Storage Temperature | Tstg | -55 | - | 150 | °C | - |
Instructions for Use:
Handling Precautions:
- The CS10N65F is sensitive to electrostatic discharge (ESD). Handle with care and use proper ESD protection.
- Avoid exposing the device to temperatures outside the specified range.
Mounting:
- Ensure proper heat sinking to manage junction temperature, especially during high current operation.
- Follow recommended PCB layout guidelines to minimize parasitic inductances and improve performance.
Biasing:
- Apply gate voltage (VGS) within the specified range to avoid damage or improper operation.
- Use appropriate gate drive circuits to ensure fast and clean switching transitions.
Operation:
- Do not exceed the maximum ratings for drain-source voltage (VDS), continuous drain current (ID), and pulse drain current (Ipp).
- Monitor the junction temperature (Tj) to prevent overheating.
Testing:
- Use specified test conditions for accurate parameter measurements.
- Refer to the datasheet for detailed testing procedures and equipment recommendations.
Storage:
- Store in a dry, cool place away from direct sunlight and sources of heat.
- Keep in original packaging until ready for use to protect against moisture and static damage.
Inquiry - CS10N65F