Share:


30J122A

Specifications

SKU: 8847837

BUY 30J122A https://www.utsource.net/itm/p/8847837.html

Parameter Symbol Min Typ Max Unit Description
Breakdown Voltage V(BR) - 30 - V Minimum reverse voltage
Maximum Repetitive Peak Reverse Voltage V(RRM) - 45 - V Peak reverse voltage
Maximum Average Forward Rectified Current (Tc=75°C) IF(AV) - 12 - A Continuous forward current
Non-Repetitive Peak Forward Surge Current (8.3/400μs) IFSM - 120 - A Peak surge current
Forward Voltage Drop (IF=12A, Tc=75°C) V(F) - 1.2 - V Voltage drop at rated current
Reverse Leakage Current (VR=30V, Tj=25°C) IR - 100 - μA Leakage current at rated voltage
Junction Capacitance (VR=0V, f=1MHz) Cj - 10 - pF Capacitance at zero bias
Operating Temperature Range Tj -55 - 150 °C Junction temperature range
Storage Temperature Range Tstg -65 - 150 °C Storage temperature range

Instructions for Use:

  1. Mounting:

    • Ensure proper heat sinking to maintain the junction temperature within the specified range.
    • Use appropriate mounting hardware to secure the device.
  2. Wiring:

    • Connect the anode (A) to the positive side of the circuit.
    • Connect the cathode (K) to the negative side of the circuit.
  3. Surge Handling:

    • The device can handle non-repetitive peak forward surge currents up to 120A for 8.3/400μs pulses. Ensure that the surge conditions do not exceed these limits.
  4. Thermal Management:

    • Monitor the junction temperature to ensure it does not exceed 150°C. Proper thermal management is crucial for reliable operation.
  5. Reverse Voltage:

    • Do not apply reverse voltages exceeding 45V to avoid damage to the device.
  6. Forward Current:

    • The maximum average forward rectified current is 12A at a case temperature of 75°C. Ensure that the current does not exceed this value to prevent overheating.
  7. Storage:

    • Store the device in a dry environment with temperatures between -65°C and 150°C to maintain its performance characteristics.
  8. Testing:

    • Before installation, perform a visual inspection to ensure there are no physical damages.
    • Test the device using standard diode testing procedures to verify its functionality.
  9. Handling:

    • Handle the device with care to avoid mechanical stress or damage to the leads.
    • Use anti-static precautions to prevent electrostatic discharge (ESD) damage.
(For reference only)

 Inquiry - 30J122A