Share:


TGAN40N60F2DS

Specifications

SKU: 8847862

BUY TGAN40N60F2DS https://www.utsource.net/itm/p/8847862.html

Parameter Symbol Min Typical Max Unit Notes
Drain-Source Voltage VDS - 600 - V Continuous
Gate-Source Voltage VGS -20 - 20 V Continuous
Drain Current ID - 40 - A @ TC = 25°C
Power Dissipation PTOT - - 218 W @ TC = 25°C
Junction Temperature TJ - - 175 °C Maximum
Storage Temperature TSTG -65 - 150 °C -
Thermal Resistance, Junction to Case RθJC - 0.5 - °C/W -
Total Gate Charge QG - 130 - nC @ VGS = 15V, ID = 40A
Input Capacitance Ciss - 2200 - pF @ VDS = 400V, f = 1MHz
Output Capacitance Coss - 290 - pF @ VDS = 400V, f = 1MHz
Reverse Transfer Capacitance Crss - 210 - pF @ VDS = 400V, f = 1MHz
Turn-On Delay Time td(on) - 40 - ns @ VGS = 15V, ID = 40A
Rise Time tr - 50 - ns @ VGS = 15V, ID = 40A
Turn-Off Delay Time td(off) - 45 - ns @ VGS = 15V, ID = 40A
Fall Time tf - 55 - ns @ VGS = 15V, ID = 40A

Instructions:

  1. Handling and Storage:

    • Store in a dry, cool place away from direct sunlight.
    • Handle with care to avoid mechanical damage.
  2. Mounting:

    • Ensure proper thermal management by using a heatsink or cooling solution.
    • Use a thermal interface material (TIM) between the device and heatsink for optimal heat dissipation.
    • Tighten screws to the recommended torque values to ensure good thermal contact.
  3. Electrical Connections:

    • Connect the drain, source, and gate terminals correctly to avoid damage.
    • Use short, low-inductance leads to minimize parasitic inductance.
  4. Gate Drive:

    • Apply a gate voltage within the specified range to ensure reliable operation.
    • Use a gate resistor to control switching speed and reduce EMI.
  5. Operating Conditions:

    • Do not exceed the maximum ratings for drain-source voltage, gate-source voltage, and drain current.
    • Monitor the junction temperature to ensure it remains within safe limits.
  6. Testing:

    • Perform initial testing under controlled conditions to verify proper operation.
    • Use appropriate test equipment and procedures to avoid damaging the device.
  7. Safety:

    • Follow all safety guidelines when handling high-voltage and high-current circuits.
    • Use protective equipment as necessary.
(For reference only)

 Inquiry - TGAN40N60F2DS