Specifications
SKU: 8937960
Parameter | Description | Value |
---|---|---|
Part Number | Full part number | SJPL-D2VL |
Type | Device type | PhotoMOS Relay |
Package | Package type | SOP-4 |
Input Voltage (VI) | Maximum input voltage | 30VDC |
Input Current (II) | Maximum input current | 10mA |
Output Voltage (VO) | Maximum output voltage | 60VDC |
Output Current (IO) | Maximum output current | 2A |
Isolation Voltage | Dielectric strength | 2500VAC (1 minute) |
Insulation Resistance | Minimum insulation resistance at 500VDC | 100MΩ |
Contact Form | Output contact configuration | SPST-NO (Single Pole Single Throw - Normally Open) |
Operating Temperature | Operating temperature range | -40°C to +85°C |
Storage Temperature | Storage temperature range | -40°C to +125°C |
Humidity | Relative humidity | 5% to 95% (non-condensing) |
Life Expectancy | Mechanical life | 10 million operations |
Electrical Life | Electrical life (at rated load) | 100,000 operations |
Turn-On Time | Maximum turn-on time | 1ms |
Turn-Off Time | Maximum turn-off time | 0.5ms |
Leakage Current | Maximum leakage current (OFF state) | 1μA |
Instructions for Use
Handling Precautions:
- Handle with care to avoid damage to the device.
- Use appropriate ESD (Electrostatic Discharge) protection measures.
Mounting:
- Ensure the PCB (Printed Circuit Board) is clean and free from contaminants.
- Follow the recommended soldering profile to avoid thermal stress.
Wiring:
- Connect the input side (control circuit) to the control signal source.
- Connect the output side (load circuit) to the load and power supply.
- Ensure correct polarity for both input and output connections.
Operation:
- Apply the control voltage to the input pins to activate the relay.
- The output contacts will close when the relay is activated, allowing current to flow through the load.
- Remove the control voltage to deactivate the relay, which will open the output contacts.
Testing:
- Test the relay in a controlled environment to ensure it meets the specified parameters.
- Use a multimeter to verify continuity across the output contacts when the relay is activated.
Storage:
- Store in a dry, cool place away from direct sunlight and corrosive substances.
- Keep in original packaging until ready for use to prevent static damage.
Troubleshooting:
- If the relay fails to operate, check the control voltage and current.
- Verify that the load is within the rated specifications.
- Inspect the relay for physical damage or signs of overheating.
Disposal:
- Dispose of the device according to local environmental regulations.
- Do not incinerate or dispose of in household waste.