Specifications
SKU: 8941817
Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
---|---|---|---|---|---|---|
Forward Voltage (IF = 20mA) | VF | - | 1.2 | 1.6 | V | IF = 20mA |
Peak Forward Current | IF(surge) | - | - | 1.5 | A | tp = 10ms, Repetition Rate 10% |
Continuous Forward Current | IF | - | 20 | 50 | mA | TA = 25°C |
Reverse Voltage | VRRM | - | - | 5 | V | - |
Reverse Current (VR = 5V) | IR | - | 0.1 | 1 | μA | VR = 5V |
Output Current (VCE(sat) = 0.4V) | IC | - | 100 | 150 | mA | VCE(sat) = 0.4V |
Collector-Emitter Saturation Voltage (IC = 100mA) | VCE(sat) | - | 0.4 | 0.7 | V | IC = 100mA |
Storage Temperature Range | TSTG | -40 | - | 100 | °C | - |
Operating Temperature Range | TA | -40 | - | 85 | °C | - |
Instructions for Using TLP183:
Forward Voltage (VF):
- Ensure that the forward voltage across the LED does not exceed 1.6V when the forward current is 20mA to avoid damaging the device.
Peak Forward Current (IF(surge)):
- The device can handle peak currents up to 1.5A for a pulse duration of 10ms with a repetition rate of 10%. Exceeding these limits can cause permanent damage.
Continuous Forward Current (IF):
- The continuous forward current should not exceed 50mA at ambient temperature (TA = 25°C). Higher temperatures may require derating the current.
Reverse Voltage (VRRM):
- The maximum reverse voltage that can be applied is 5V. Exceeding this value can lead to breakdown and potential damage.
Reverse Current (IR):
- The reverse current should be kept below 1μA when a reverse voltage of 5V is applied to ensure reliable operation.
Output Current (IC):
- The output current should not exceed 150mA to maintain the collector-emitter saturation voltage within safe limits.
Collector-Emitter Saturation Voltage (VCE(sat)):
- When the output current is 100mA, the collector-emitter saturation voltage should be between 0.4V and 0.7V. Higher voltages indicate the device may be approaching its limits.
Storage Temperature Range (TSTG):
- Store the device in an environment where the temperature ranges from -40°C to 100°C to prevent damage.
Operating Temperature Range (TA):
- The device is designed to operate within an ambient temperature range of -40°C to 85°C. Ensure proper heat dissipation if operating near the upper limit.
Handling Precautions:
- Handle the device with care to avoid mechanical stress.
- Use appropriate ESD protection measures to prevent electrostatic discharge damage.
- Ensure all connections are secure and correctly wired to prevent short circuits or open circuits.