Share:


FGW75N60HD

Specifications

SKU: 8941827

BUY FGW75N60HD https://www.utsource.net/itm/p/8941827.html

Parameter Symbol Value Unit
Maximum Drain-to-Source Voltage VDS(max) 600 V
Maximum Gate-to-Source Voltage VGS(max) ±20 V
Continuous Drain Current (TC = 25°C) ID(25°C) 75 A
Continuous Drain Current (TC = 100°C) ID(100°C) 55 A
Pulse Drain Current (TC = 25°C, 10 ms, 1% Duty Cycle) IDpeak(25°C) 225 A
Power Dissipation (TC = 25°C) PD(25°C) 375 W
Junction Temperature Range TJ -55 to +175 °C
Storage Temperature Range TSTG -55 to +175 °C
Total Device Dissipation (TA = 25°C) PTOT(25°C) 375 W
Thermal Resistance, Junction to Case RthJC 0.5 °C/W
Thermal Resistance, Junction to Ambient RthJA 40 °C/W

Instructions for Use:

  1. Mounting and Handling:

    • Ensure that the device is mounted on a heatsink with adequate thermal conductivity to maintain junction temperature within safe limits.
    • Use proper handling techniques to avoid damage to the device, especially during soldering.
  2. Electrical Connections:

    • Connect the drain, source, and gate terminals correctly to avoid short circuits or incorrect biasing.
    • Use short leads and wide traces to minimize inductance and resistance in the circuit.
  3. Gate Drive:

    • Apply a gate voltage (VGS) between 10V and 15V for optimal performance.
    • Ensure that the gate drive circuit can provide sufficient current to charge and discharge the gate capacitance quickly.
  4. Thermal Management:

    • Monitor the junction temperature (TJ) to ensure it does not exceed 175°C.
    • Use thermal paste or thermal interface materials to enhance heat transfer from the device to the heatsink.
  5. Overcurrent Protection:

    • Implement overcurrent protection to prevent damage due to excessive current.
    • Consider using a current-limiting resistor or a fuse in series with the drain.
  6. Storage and Transportation:

    • Store the device in a dry, cool place away from direct sunlight.
    • Handle the device with care to avoid mechanical stress or damage.
  7. Testing:

    • Before final assembly, test the device under controlled conditions to ensure it meets the specified parameters.
    • Use appropriate test equipment and procedures to avoid damaging the device.
  8. Compliance:

    • Ensure that the device complies with all relevant safety and regulatory standards for your application.
(For reference only)

 Inquiry - FGW75N60HD