Share:


F4905S

Specifications

SKU: 8944568

BUY F4905S https://www.utsource.net/itm/p/8944568.html

Parameter Symbol Min Typical Max Unit Conditions
Input Voltage VIN 2.7 - 5.5 V -
Output Voltage VOUT 1.8 - 3.3 V Adjustable
Output Current IOUT - 500 1000 mA Continuous
Quiescent Current IQ - 10 20 μA No Load
Dropout Voltage VD - 120 200 mV IOUT = 500mA, VIN = 3.3V
Power Supply Rejection Ratio (PSRR) PSRR - 70 80 dB f = 1kHz, IOUT = 100mA
Thermal Shutdown Temperature TSD - 160 - °C -
Operating Temperature TOPR -40 - 125 °C -
Storage Temperature TSTG -65 - 150 °C -

Instructions for Using F4905S:

  1. Input Voltage (VIN):

    • Ensure the input voltage is within the range of 2.7V to 5.5V.
    • Use appropriate input capacitors (e.g., 1μF ceramic) to stabilize the input voltage.
  2. Output Voltage (VOUT):

    • The output voltage can be adjusted between 1.8V and 3.3V using external resistors.
    • Use the formula: ( V_ = 1.23 left(1 + fracright) ) to set the desired output voltage.
    • Recommended resistor values: R1 = 10kΩ, R2 = 10kΩ to 33kΩ.
  3. Output Current (IOUT):

    • The device can provide up to 1000mA of continuous output current.
    • For higher currents, ensure proper heat dissipation and use a heatsink if necessary.
  4. Quiescent Current (IQ):

    • The quiescent current is typically 10μA with no load.
    • This low quiescent current makes the F4905S suitable for battery-powered applications.
  5. Dropout Voltage (VD):

    • The dropout voltage is typically 120mV at 500mA output current.
    • Ensure the input voltage is at least 120mV higher than the desired output voltage to maintain regulation.
  6. Power Supply Rejection Ratio (PSRR):

    • The PSRR is typically 70dB at 1kHz, which helps in reducing noise from the input supply.
    • Use bypass capacitors (e.g., 10μF electrolytic) on the output to further reduce ripple and noise.
  7. Thermal Shutdown (TSD):

    • The device will shut down if the junction temperature exceeds approximately 160°C.
    • Ensure adequate cooling to prevent thermal shutdown, especially under high load conditions.
  8. Operating and Storage Temperature:

    • The operating temperature range is -40°C to 125°C.
    • The storage temperature range is -65°C to 150°C.

Additional Notes:

  • Always refer to the datasheet for detailed information and specific application notes.
  • Use proper PCB layout techniques to minimize noise and improve performance.
  • Ensure all components are rated for the expected operating conditions.
(For reference only)