Specifications
SKU: 8979687
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Supply Voltage | VDD | 2.7 | - | 5.5 | V | Operating voltage range |
Supply Current (Active) | IDD | - | 2.5 | - | mA | Current consumption in active mode |
Supply Current (Shutdown) | ISD | - | 0.1 | - | μA | Current consumption in shutdown mode |
Output Type | - | - | - | - | Open Drain | Output configuration |
Output Low Voltage | VOL | - | 0.4 | - | V | Output voltage when low |
Output High Impedance | ZOH | - | - | - | Ω | Output impedance when high |
Input Threshold Voltage | VIH | 2.0 | - | 5.5 | V | Input voltage for logic high |
Input Threshold Voltage | VIL | 0.8 | - | 2.0 | V | Input voltage for logic low |
Operating Temperature | TOPR | -40 | - | 85 | °C | Operating temperature range |
Storage Temperature | TSTG | -65 | - | 150 | °C | Storage temperature range |
Maximum Junction Temperature | TJMAX | - | - | 150 | °C | Maximum junction temperature |
ESD Rating | HBM | - | - | 2000 | V | Human Body Model (HBM) ESD rating |
Package Type | - | - | - | - | SOT-23 | Package type |
Instructions for Use:
Power Supply:
- Ensure the supply voltage (VDD) is within the range of 2.7V to 5.5V.
- Connect the VDD pin to the positive supply and GND pin to the ground.
Output Configuration:
- The output is open drain, so an external pull-up resistor is required to define the high state.
- Choose a pull-up resistor value based on the load and desired rise time.
Input Signal:
- Apply input signals within the specified threshold voltages (VIL and VIH).
- Ensure the input signal is stable and noise-free to avoid false triggering.
Temperature Considerations:
- Operate the device within the temperature range of -40°C to 85°C.
- Store the device within the temperature range of -65°C to 150°C.
ESD Protection:
- Handle the device with care to avoid damage from electrostatic discharge.
- Use proper ESD protection measures during handling and assembly.
Shutdown Mode:
- To enter shutdown mode, set the enable pin to a low state.
- In shutdown mode, the current consumption drops to approximately 0.1 μA.
Mounting and Handling:
- Follow standard surface mount technology (SMT) guidelines for mounting the SOT-23 package.
- Avoid excessive thermal stress during soldering.
Testing:
- Before final assembly, test the device under typical operating conditions to ensure proper functionality.
- Verify the output behavior with and without the pull-up resistor.
Inquiry - TSF30L200C